Station, Object, Action, New Serial, Old Serial#, StartDate,EndDate,TaskName,Notes1,Notes2,Notes3 "" "Air Temp Sensor" "Replaced" "" "" 03/08/1995 03/08/1995 "Data logger replaced" "" "" "" "" "T&H sensor" "Observation" "" "" 16/10/1998 04/11/1998 "Comments about tower Temp & Hum." "" "" "" "" "Datalogger" "Replaced" "" "" 18/06/1993 18/06/1993 "Replace datalogger #5" "Data logger replaced. Air temperature data were bad, but the sensors were okay. No indication of which heights on the tower were affected." "" "" "" "Psychrometer" "Repaired" "" "" 19/06/1986 19/06/1986 "Fix Psychrometer" "Replaced datalogger because it wasn't working" "" "" "" "T&H sensor" "Observation" "" "" 19/11/1998 17/12/1998 "Comments about tower Temp & Hum." "" "" "" "" "" "Observation" "" "" 30/12/1985 05/01/1986 "Data lost" "" "" "" "BCI Office" "Barometer" "Reprogrammed" "" "" 07/11/1997 07/11/1997 "Adjust pressure on sensor" "Adjusted the pressure by lowering it by 1.7mmHg" "" "" "BCI Office" "Barometer" "Discontinued" "" "" 09/04/2007 09/04/2007 "Stop recording manual air pressure" "Barometer was damaged and unrepairable" "" "" "BCI Office" "Barometer" "Observation" "" "" 12/10/2006 12/10/2006 "Suspect data." "" "" "" "BCI Office" "Barometer" "Moved" "" "" 18/01/1996 18/01/1996 "Move barometer to new office" "ISCO registering too high" "" "" "BCI Office" "Barometer" "Reprogrammed" "" "" 27/09/1996 27/09/1996 "Adjust pressure on sensor" "Adjusted the pressure from 758.8 to 756.2" "" "" "Clearing" "ETGage" "Replaced" "" "" 01/02/1999 01/02/1999 "Replace ETGage near evaporation tank" "" "" "" "Clearing" "Datalogger" "Reprogrammed" "" "" 01/04/1999 01/04/1999 "Modify program to remove unused sensor outputs" "" "" "" "Clearing" "ETGage" "Deactivated" "" "" 01/06/1998 02/06/1998 "Remove ETGage #1" "Sensor reading badly on the 22nd, however on the 23rd reading correctly" "" "" "Clearing" "ETGage" "Modified" "" "" 01/12/2009 01/12/2009 "Replace GorTex covering on ETGage#1" "Probably accidentally disconnected by workers. ISCO worked during the day, but not at night" "" "" "Clearing" "ETGage" "Cleaned" "" "" 01/12/2011 01/12/2011 "Replace GorTex covering on ETGage" "Tipping bucket found knocked over on Jan 4. No good data since Dec 24" "" "" "Clearing" "Tipping Bucket" "Calibrated" "" "" 02/01/2012 02/01/2012 "Calibrate Tipping bucket" "October 17, 2012 Calibrated the TB from the Clearing Poured 628cc of water and got 19.812mm of rainfall in 20minutes. Done with a CS206 logger. After the test there was a little bit of water left on the tipping mechanism. which was emptied out. The test" "was run from 11:30 to 11:55am" "" "Clearing" "Tipping Bucket" "Observation" "" "" 02/05/1990 02/05/1990 "Tipping bucket plugged. Some rainfall not recorded" "Air temperature sensor giving bad values. Replaced" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 02/05/2012 02/05/2012 "Clean Tipping bucket" "" "" "" "Clearing" "Lab Building" "Replaced" "NA" "NA" 02/06/2016 02/06/2016 "Replaced clearing max thermometer" "" "" "" "Clearing" "T&H sensor" "Modified" "" "" 02/07/2013 02/07/2013 "Replace radiation shield" "" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 02/09/1999 02/09/1999 "Hobo #3 tipping bucket Cleaned." "" "" "" "Clearing" "ETGage" "Observation" "" "" 02/11/2005 11/11/2005 "Bad data" "Water gets inside gauge when it rains heavily" "" "" "Clearing" "" "Observation" "" "" 02/12/1998 02/12/1998 "Trees cut in Clearing. Station no longer in shadow" "Stilling pond sediment cleaned. Data good beginning on the 11th" "" "" "Clearing" "ETGage" "Modified" "" "" 02/12/2009 02/12/2009 "Replace GorTex covering on ETGage#2" "" "" "" "Clearing" "Tipping Bucket" "Observation" "" "" 03/01/1996 03/01/1996 "Missing data" "Data missing beginning the previous night" "" "" "Clearing" "Air Temp Sensor" "Observation" "" "" 03/01/1996 03/01/1996 "Missing data" "Data missing beginning the previous night" "" "" "Clearing" "" "Observation" "" "" 03/02/1992 03/02/1992 "Demolition of Animal house begins" "The elimination of the Animal House may affect temperatures in the Clearing" "" "" "Clearing" "Thermometer" "Moved" "" "" 03/04/1995 03/04/1995 "Move orientation of max/min thermometer to horizontal" "" "" "" "Clearing" "ETGage" "Cleaned" "" "" 03/07/2007 03/07/2007 "Replace GorTex covering on ETGage" "" "" "" "Clearing" "" "Observation" "" "" 03/08/1999 03/08/1999 "Large branch fell in Clearing possibly altering local environment" "" "" "" "Clearing" "Anemometer" "Installed" "" "" 03/09/1999 03/09/1999 "Install Anemometer near evaporation tank" "" "" "" "Clearing" "Tipping Bucket" "Observation" "" "" 04/03/1991 05/03/1991 "Tipping bucket not working during this period" "Tipping bucket replaced at 15:00hr" "" "" "Clearing" "Datalogger" "Replaced" "" "" 04/04/2006 04/04/2006 "Replace Datalogger" "Clock was reading one day ahead" "" "" "Clearing" "Tipping Bucket" "Repaired" "" "" 04/05/1999 04/05/1999 "Hobo #1 tipping bucket blocked. Cleaned." "" "" "" "Clearing" "Totalizing Anemometer" "Installed" "" "" 04/08/1988 04/08/1988 "Install Totalizing anemometer in Clearing" "" "" "" "Clearing" "ETGage" "Observation" "" "" 04/11/2003 04/11/2003 "Calibration ETGage fell" "" "" "" "Clearing" "Tipping Bucket" "Replaced" "" "" 05/03/1991 05/03/1991 "Replace Tipping bucket" "" "" "" "Clearing" "Psychrometer" "Replaced" "" "" 05/03/2004 05/03/2004 "Replace Psychrometer after old one broke" "" "" "" "Clearing" "" "Observation" "" "" 05/05/2008 05/05/2008 "Several shrubs near Clearing cut down" "" "" "" "Clearing" "RH sensor" "Observation" "" "" 05/10/1989 05/10/1989 "Problem with sensor. Data suspect" "" "" "" "Clearing" "Tipping Bucket" "Replaced" "" "" 05/12/1997 05/12/1997 "Replace Tipping bucket" "" "" "" "Clearing" "Pyranometer" "Reprogrammed" "" "" 05/12/1997 05/12/1997 "Change program to correct errors with pyranometer data" "" "" "" "Clearing" "Telemetry" "Installed" "" "" 06/06/2008 06/06/2008 "Install radio telemetry system" "" "" "" "Clearing" "Thermometer" "Replaced" "" "" 06/07/2010 06/07/2010 "Replace Max/Min thermometers" "Thermometers replaced because paint on temperature scale came off." "" "" "Clearing" "" "Observation" "" "" 06/09/1999 23/09/1999 "Large tree removed from Clearing" "" "" "" "Clearing" "Thermometer" "Installed" "" "" 06/10/2011 06/10/2011 "Reinstall Max/Min 'U' thermometers" "" "" "" "Clearing" "ETGage" "Observation" "" "" 06/10/2015 06/10/2015 "Something inside ETGage #2 glass tube" "" "" "" "Clearing" "ETGage" "Replaced" "" "" 07/02/1997 07/02/1997 "Replace ETGage" "" "" "" "Clearing" "ETGage" "Observation" "" "" 07/02/2011 07/02/2011 "Bad data ETGage Calib" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Clearing" "RH sensor" "Observation" "" "" 07/08/1989 07/08/1989 "Wet-bulb sensor dry" "" "" "" "Clearing" "Tipping Bucket" "Observation" "" "" 07/10/1999 07/10/1999 "Hobo #4 tipping bucket not working" "" "" "" "Clearing" "ETGage" "Cleaned" "" "" 08/01/2014 08/01/2014 "Clean ETGage #2 and replace GorTex covering" "Water level momentarily too high while stilling pond was refilled after cleaning" "" "" "Clearing" "Rain Gauge" "Observation" "" "" 08/03/1999 08/03/1999 "Rain gauge #2 was plugged" "Rain gauge funnel plugged. Cleaned at 9:25hr" "" "" "Clearing" "Tipping Bucket" "Repaired" "" "" 08/03/1999 08/03/1999 "Hobo #2 tipping bucket blocked. Cleaned." "" "" "" "Clearing" "BP sensor" "Installed" "K1040006" "" 08/05/2014 08/05/2014 "Installed Vaisala Barometer" "May 8th, 2014 Data logger shutdown at 9:50 am - Installed barometer Vaisala PTB110 SN:K1040006 Data logger powered up at 9:55 am The previous barometer was removed on Dec. 19, 2013 at 10:45 am -CS105 PTB101B bar pressure sensor SN:A3110020 -A3110020 Se" "nsor malfuctioning since Dec. 12, 2013 at 10:45 am" "" "Clearing" "ETGage" "Observation" "" "" 08/06/2010 08/06/2010 "Bad data" "" "" "" "Clearing" "ETGage" "Observation" "" "" 08/08/1994 08/08/1994 "Questionable data" "ETGage value on this date is questionable" "" "" "Clearing" "ETGage" "Observation" "" "" 08/09/1997 09/09/1997 "Bad data" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Clearing" "Tipping Bucket" "Repaired" "" "" 08/10/1999 08/10/1999 "Hobo #3 tipping bucket blocked. Cleaned." "" "" "" "Clearing" "Totalizing Anemometer" "Discontinued" "" "" 08/10/2001 08/10/2001 "Discontinue use of Totalizing anemometer in the Clearing" "Moved to Tower" "" "" "Clearing" "ETGage" "Cleaned" "" "" 08/10/2015 08/10/2015 "Clean ETGage #2" "Change program to correct totalizing PAR calculations" "" "" "Clearing" "Thermometer" "Installed" "" "" 09/01/1995 09/01/1995 "Install new Max/Min thermometer" "Installed new max/min thermometer. Old thermometer left in place for comparison" "" "" "Clearing" "Psychrometer" "Replaced" "" "" 09/09/2013 09/09/2013 "Replace Psychrometer after old one broke" "" "" "" "Clearing" "Datalogger" "Observation" "" "" 09/10/2009 09/10/2009 "Battery giving problems" "" "" "" "Clearing" "Datalogger" "Battery Replaced" "" "" 09/10/2009 09/10/2009 "Replace Datalogger battery" "The datalogger was not working during the nights" "" "" "Clearing" "ETGage" "Observation" "" "" 09/11/2010 09/11/2010 "Bad data in ETGage#1" "Thermometers replaced because paint on temperature scale came off." "" "" "Clearing" "Thermometer" "Replaced" "" "" 09/11/2010 09/11/2010 "Replace Max/Min thermometers" "" "" "" "Clearing" "Tipping Bucket" "Repaired" "" "" 10/02/1999 10/02/1999 "Hobo tipping bucket blocked. Cleaned." "" "" "" "Clearing" "BP sensor" "Replaced" "A3110002" "Z0630032" 10/03/2010 10/03/2010 "Replace Bar Pressure sensor" "Replaced the Bar Pressure sensor. Station Shutdown at 10:43 a.m. Removed -Removed pressure transducer Vaisala PTB101B S/N Z0630032 Installed -Installed pressure transducer Vaisala PTB101B S/N A3110002 Station Powerup time at 11:07 a.m." "" "" "Clearing" "ETGage" "Observation" "" "" 10/05/1994 10/05/1994 "Questionable data" "" "" "" "Clearing" "Tipping Bucket" "Repaired" "" "" 10/05/1999 10/05/1999 "Hobo #1 tipping bucket blocked. Cleaned." "" "" "" "Clearing" "Tipping Bucket" "Repaired" "" "" 10/05/1999 10/05/1999 "Hobo #2 tipping bucket blocked. Cleaned." "" "" "" "Clearing" "Psychrometer" "Replaced" "" "" 10/11/1994 10/11/1994 "Replace Pyschrometer" "Thermometer broke on New pyschrometer. Now using old psychrometer. Units now in F" "" "" "Clearing" "Datalogger" "Reprogrammed" "" "" 11/05/2014 11/05/2014 "Loaded new Datalogger program" "May 11, 2014 On May 11, 2014 at 11:10 am -Loaded the program bci_clear_20140511kk.CR1 -This program was properly adjusted for the operation of the CS106 (PTB110) barometer -VoltSe() instruction with 0.240 multiplier and 500 offset value -It replaced the" "previous program bci_clear_20131023kk.CR1 which was used with CS105 vaisala barometer." "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 11/06/1999 11/06/1999 "Hobo #1 tipping bucket Cleaned." "Cleaned at 9:25hr" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 11/06/1999 11/06/1999 "Hobo #2 tipping bucket Cleaned." "" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 11/06/1999 11/06/1999 "Hobo #3 tipping bucket Cleaned." "Cleaned at 9:25hr" "" "" "Clearing" "Thermometer" "Replaced" "" "" 11/12/1987 11/12/1987 "Replace Max/Min thermometer" "" "" "" "Clearing" "T&H sensor" "Modified" "" "" 11/12/2012 11/12/2012 "Replace radiation shield" "Water level momentarily too high while stilling pond was refilled after cleaning. Level correct on the 14th" "" "" "Clearing" "" "Observation" "" "" 11/12/2013 19/12/2013 "Cut trees around Clearing" "" "" "" "Clearing" "ETGage" "Observation" "" "" 12/02/1998 13/02/1998 "Bad data" "" "" "" "Clearing" "ETGage" "Observation" "" "" 12/03/1996 12/03/1996 "Questionable data" "Heavy rain caused water to enter the ETGage" "" "" "Clearing" "Thermometer" "Discontinued" "" "" 12/04/2011 12/04/2011 "Stopped using old 'U' max/min thermometer" "" "" "" "Clearing" "ETGage" "Observation" "" "" 12/05/1997 12/05/1997 "Bad data" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Clearing" "Datalogger" "Observation" "" "" 12/10/2009 12/10/2009 "Datalogger not working. Could not download data" "" "" "" "Clearing" "Rain Gauge" "Cleaned" "" "" 12/10/2009 12/10/2009 "Clean Rain gauges" "The datalogger was not working during the nights" "" "" "Clearing" "BP sensor" "Observation" "A3110020" "" 12/12/2013 12/12/2013 "Bar Pressure Sensor not working" "Dec. 19, 2013 10:45Sensor malfuctioning since Dec. 12, 2013" "" "" "Clearing" "RH sensor" "Observation" "" "" 13/02/1986 24/02/1986 "Sensor not working" "" "" "" "Clearing" "ETGage" "Deactivated" "" "" 13/02/1998 13/02/1998 "Remove bad ETGage" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Clearing" "ETGage" "Cleaned" "" "" 13/04/1995 13/04/1995 "Clean ETGage" "" "" "" "Clearing" "Battery" "Replaced" "" "" 13/10/2009 13/10/2009 "Replace battery and charger" "Battery reading low at night, sometimes 9.42V.Replacing Battery and Charger." "" "" "Clearing" "Datalogger" "Replaced" "4937" "X14483" 13/10/2009 13/10/2009 "Replace datalogger with new model" "On October12, 2009 it was not possible to downloand data from the installed logger at BCI Clear - Faulty CR10XPB Logger. On October 13, 2009 we proceeded with the Installation of a new data logger CR206 New Program (bcCL20091013.CR2) sent and compiled on" " Oct. 13, 2009 at 11:13 a.m. New Logger CR206 SN:4937 Old Logger CR10XPB SN:X14483 (The Older Logger was later sent to CampbellSCI for calibrated on 25-Feb-2010 and it was found to be in OPERATIONAL FAILURE)" "" "Clearing" "T&H sensor" "Replaced" "E4046" "Z2750040" 13/10/2009 13/10/2009 "Replace T&H sensor with new model" "Installing new temperature and RH sensor along with a new radiation shield - 6 gill RM Young.New Temp and RH CS215 SN: E4046 (contains a brand new sensirion chip and cap) Removed Old Temp&RH sensor CS500-L SN: Z2750040" "" "" "Clearing" "T&H sensor" "Replaced" "E10766" "E4046" 14/02/2014 14/02/2014 "Replaced T&RH Sensor" "Feb. 14, 2014 Logger shutdown at 10:25 am Installed new CS215 T&RH Sensor SN:E10766 Removed CS215 T&RH Sensor SN:E4046 Logger power-up at 10:47 am" "" "" "Clearing" "RH sensor" "Observation" "" "" 14/08/1989 14/08/1989 "Wet-bulb sensor dry" "" "" "" "Clearing" "ETGage" "Cleaned" "" "" 14/08/2013 14/08/2013 "Clean ETGages and replace GorTex coverings" "" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 14/09/1999 14/09/1999 "Hobo #2 tipping bucket Cleaned." "" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 14/09/1999 14/09/1999 "Hobo #3 tipping bucket Cleaned." "" "" "" "Clearing" "Tipping Bucket" "Observation" "" "" 14/09/1999 14/09/1999 "Hobo #4 tipping bucket not working" "" "" "" "Clearing" "ETGage" "Observation" "" "" 14/09/2001 14/09/2001 "Bad data" "" "" "" "Clearing" "T&H sensor" "Chip Replaced" "4046" "" 14/10/2011 14/10/2011 "Change T&H sensor chip" "October 14, 2011 Logger shutdown at 10:27 -Changed the CS215 SN:4046 T&RH chip Logger startup at 11:41" "" "" "Clearing" "Tipping Bucket" "Calibrated" "97-873" "" 14/10/2011 14/10/2011 "Calibrate and clean Tipping bucket" "October 14, 2011 Logger shutdown at 10:27 -Calibrated clearing TB - poured 314cc of water and got 9.4mm of rain - TB will be replaced -Cleaned the TB siphon Logger startup at 11:41" "" "" "Clearing" "ETGage" "Installed" "" "" 15/01/2002 15/01/2002 "Install second, calibration ETGage in Clearing" "" "" "" "Clearing" "" "Replaced" "E12903" "E10766" 15/02/2016 15/02/2016 "Replaced AirTemp sensor" "" "" "" "Clearing" "BP sensor" "Replaced" "6469625" "K1040005" 15/02/2016 15/02/2016 "Replaced Bar pressure sensor" "" "" "" "Clearing" "Logger" "Reprogrammed" "NA" "NA" 15/02/2016 15/02/2016 "Loaded new program" "" "" "" "Clearing" "Tipping Bucket" "Observation" "" "" 15/03/1993 15/03/1993 "Bad data" "Beginning in the third week of March, the tipping bucket has failed to record any precipitation" "" "" "Clearing" "ETGage" "Installed" "" "" 15/06/1998 15/06/1998 "Install ETGage #1" "" "" "" "Clearing" "Tipping Bucket" "Repaired" "" "" 15/07/1999 15/07/1999 "Hobo #2 tipping bucket blocked. Cleaned." "" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 15/07/1999 15/07/1999 "Hobo #1 tipping bucket Cleaned." "" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 15/07/1999 15/07/1999 "Hobo #2 tipping bucket Cleaned." "" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 15/07/1999 15/07/1999 "Hobo #3 tipping bucket Cleaned." "" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 15/07/1999 15/07/1999 "Hobo #4 tipping bucket Cleaned." "" "" "" "Clearing" "Psychrometer" "Replaced" "" "" 15/07/2005 15/07/2005 "Replace Psychrometer after old one broke" "" "" "" "Clearing" "ETGage" "Replaced" "" "" 15/11/2005 15/11/2005 "Replace ETGage" "Water gets inside gauge when it rains heavily" "" "" "Clearing" "Psychrometer" "Replaced" "" "" 15/12/2004 15/12/2004 "Replace Psychrometer after old one broke" "Replace Temp/Hum sensor at 10:30hr" "" "" "Clearing" "ETGage" "Observation" "" "" 16/01/1996 16/01/1996 "Questionable data" "Heavy rain caused water to enter the ETGage" "" "" "Clearing" "Rain Gauge" "Observation" "" "" 16/01/1996 16/01/1996 "Rain gauge overflowed due to very heavy rain" "" "" "" "Clearing" "Tipping Bucket" "Repaired" "" "" 16/03/1999 16/03/1999 "Hobo #2 tipping bucket blocked. Cleaned." "Cleaned at 9:30hr" "" "" "Clearing" "Thermometer" "Observation" "" "" 16/03/2011 16/03/2011 "Max. temperature unexpectedly low" "" "" "" "Clearing" "Thermometer" "Replaced" "" "" 16/06/2010 16/06/2010 "Replace Max/Min thermometers with new model" "Installed new, straight max/min thermometers. Old 'U' thermometer kept for comparison" "" "" "Clearing" "Tipping Bucket" "Observation" "" "" 16/07/2010 16/07/2010 "Tipping bucket not working" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Clearing" "Rain Gauge" "Replaced" "" "" 16/09/1985 16/09/1985 "Replace Plastic rain gauge with 8" "Counter at 0988 when problem detected. Set to 1000 on restart" "" "" "Clearing" "Thermometer" "Replaced" "" "" 16/11/2011 16/11/2011 "Replace Max. temperature thermometer" "" "" "" "Clearing" "ETGage" "Installed" "" "" 17/03/1998 17/03/1998 "Install new ETGage" "" "" "" "Clearing" "Tipping Bucket" "Calibrated" "" "" 17/04/2009 17/04/2009 "Calibrate Tipping bucket" "Hour Dry Bulb Wet Bulb10:13 30.0 25.0" "" "" "Clearing" "Tipping Bucket" "Calibrated" "" "" 17/04/2009 17/04/2009 "Calibrate Temp&hum sensor against sling psychrometer" "Hour Dry Bulb Wet Bulb10:42 33.0 26.0" "" "" "Clearing" "Tipping Bucket" "Deactivated" "" "" 17/09/1999 17/09/1999 "Hobo #4 tipping bucket removed" "" "" "" "Clearing" "Anemometer" "Installed" "" "" 17/11/1997 17/11/1997 "Install MetOne Anemometer" "Moving sensors to side of tower should eliminate any possible shading from tipping bucket" "" "" "Clearing" "Pyranometer" "Installed" "" "" 17/11/1997 17/11/1997 "Install Pyranometer" "" "" "" "Clearing" "Datalogger" "Observation" "" "" 18/01/2002 18/01/2002 "Battery dead" "" "" "" "Clearing" "" "Observation" "" "" 18/03/2002 18/03/2002 "Trees near Clearing cut down" "" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 18/06/1999 18/06/1999 "Hobo #1 tipping bucket Cleaned." "Cleaned at 9:25hr" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 18/06/1999 18/06/1999 "Hobo #2 tipping bucket Cleaned." "" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 18/06/1999 18/06/1999 "Hobo #3 tipping bucket Cleaned." "Cleaned at 9:25hr" "" "" "Clearing" "Tipping Bucket" "Installed" "" "" 18/06/1999 18/06/1999 "Install Hobo #4 tipping bucket" "" "" "" "Clearing" "Datalogger" "Reprogrammed" "" "" 18/07/2012 01/02/2013 "Convert to MySQL" "July 18, 2012 The bci_clear station was converted to MySQL. On July 18, 2012 15:30 a new logger program bci_clear_20120718kk.CR1 was uploaded to the station. Removed the logger program bci_clear_20111215kk.CR1" "" "" "Clearing" "Psychrometer" "Replaced" "" "" 18/08/1994 18/08/1994 "Replace Pyschrometer" "New pyschrometer. Units now in Celcius" "" "" "Clearing" "Evaporation Tank" "Cleaned" "" "" 18/10/2000 18/10/2000 "Clean Tank" "ISCO recording 35mm when manual reading is 15mm" "" "" "Clearing" "ETGage" "Observation" "" "" 18/11/2003 18/11/2003 "Calibration ETGage bad data" "" "" "" "Clearing" "Tipping Bucket" "Replaced" "10-89" "97-873" 18/11/2011 18/11/2011 "Replace Tipping bucket" "November 18, 2011Replaced the TB on the clearing by a new TB The old TB was reading low according to a test conducted on Oct. 14, 2011 - See note on maintenance for Oct. 14 Installed TB3 (CS700) S/N 10-89 Removed TB3(CS700) S/N 97-873" "" "" "Clearing" "ETGage" "Replaced" "" "" 19/02/2015 19/02/2015 "Replace broken ETGage #2" "" "" "" "Clearing" "T&H sensor" "Replace shield" "" "" 19/04/2011 19/04/2011 "BCI Clear - Change T&H shields" "April 19, 2011 Changed the T&RH shield at the clearing by a clean shield. Datalogger shutdown at 11:17 Datalogger powered up at 11:27 Inspected all instruments at BCI" "" "" "Clearing" "Tipping Bucket" "Observation" "" "" 19/05/1988 23/05/1988 "Not recording correctly" "" "" "" "Clearing" "RH sensor" "Observation" "" "" 19/06/1989 19/06/1989 "Wet-bulb sensor dry" "" "" "" "Clearing" "Evaporation Tank" "Cleaned" "" "" 19/06/2002 19/06/2002 "Clean Tank" "" "" "" "Clearing" "ETGage" "Cleaned" "" "" 19/06/2014 19/06/2014 "Clean ETGages and replace GorTex coverings" "" "" "" "Clearing" "" "Observation" "" "" 19/09/2013 19/09/2013 "Cut shrubs around Clearing" "" "" "" "Clearing" "ETGage" "Replaced" "" "" 19/09/2013 19/09/2013 "Replace ETGage #1" "" "" "" "Clearing" "Datalogger" "Replaced" "36527" "4937" 19/11/2010 19/11/2010 "Replaced data logger with new model" "November 19, 2010From 9:47 to 11:43 INSTALLED: -CR1000 Datalogger SN36527 -Installed program bci_clear20101119kk.CR1 - This program had a bug: it did not read the bar pressure due to a missing delay - problem fixed on Nov. 22, 2010 REMOVED: -CR206 Data" "logger SN4937" "" "Clearing" "Tipping Bucket" "Calibrated" "" "" 19/11/2010 19/11/2010 "Calibrated tipping bucket" "November 19, 2010From 9:47 to 11:43 CALIBRATED CS700 TB raingauge: Poured 314cc of water and 9.39mm of rain" "" "" "Clearing" "BP sensor" "Deactivated" "A3110020" "" 19/12/2013 19/12/2013 "Remove Bar Pressure Sensor" "Dec. 19, 2013 10:45 Removed bar pressure sensor from BCI Clearing station. CS105 PTB101B bar pressure sensor SN:A3110020" "" "" "Clearing" "Datalogger" "Replaced" "" "" 20/01/2000 20/01/2000 "Replace Datalogger" "" "" "" "Clearing" "Psychrometer" "Replaced" "" "" 20/04/2015 20/04/2015 "Replace Psychrometer after old one broke" "" "" "" "Clearing" "ETGage" "Replaced" "NA" "NA" 20/04/2016 20/04/2016 "Redeployed ET gauge ceramic head" "" "" "" "Clearing" "Tipping Bucket" "Repaired" "" "" 20/08/1993 20/08/1993 "Repair Tipping bucket datalogger cable" "Replaced datalogger cable. This would have produced false rainfall events at 11:29hr" "" "" "Clearing" "ETGage" "Observation" "" "" 20/08/1997 20/08/1997 "Bad data" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Clearing" "Tipping Bucket" "Installed" "" "" 20/09/1999 20/09/1999 "Hobo #4 tipping bucket reinstalled" "" "" "" "Clearing" "" "Observation" "" "" 20/10/1999 20/10/1999 "Some bambo was removed near Clearing" "" "" "" "Clearing" "Datalogger" "Reprogrammed" "" "" 21/01/2000 21/01/2000 "Adjust clock" "Data logger was recording 55 minutes behind. Clock reset to correct time" "" "" "Clearing" "BP sensor" "Observation" "" "" 21/01/2000 21/01/2000 "Unusual variation in pressure after datalogger changed" "Everything looks okay" "" "" "Clearing" "Air Temp Sensor" "Observation" "" "" 21/06/1989 21/06/1989 "Air temperature data suspect" "" "" "" "Clearing" "Tipping Bucket" "Observation" "" "" 21/10/1985 21/10/1985 "Problem with Tiping bucket" "" "" "" "Clearing" "Tipping Bucket" "Replaced" "" "" 21/10/1988 21/10/1988 "Replace Datalogger for tipping bucket" "" "" "" "Clearing" "Datalogger" "Observation" "" "" 21/11/1989 27/11/1989 "Datalogger stopped working beginning at 16:00hr" "Recorder not working between the 21st and the morning of the 28th" "" "" "Clearing" "ETGage" "Observation" "" "" 22/04/1997 22/04/1997 "Bad data" "" "" "" "Clearing" "Air Temp Sensor" "Observation" "" "" 22/05/1986 31/05/1986 "Problems with some readings" "" "" "" "Clearing" "ETGage" "Observation" "" "" 22/08/2014 22/08/2014 "Bad data ETGage #2" "" "" "" "Clearing" "Tipping Bucket" "Repaired" "" "" 22/10/1985 22/10/1985 "Fix Tiping bucket" "" "" "" "Clearing" "Anemometer" "Reprogrammed" "" "" 22/10/2010 22/10/2010 "Altered program" "On October 22, 2010 at 20:21 Edited the looger program and created biCL2009103kk.CR2, which reads the Bar Pressure every 10s and calculates the corresponding average every 15min Here it is the modified Bar Press read section 'Reading Bar Press every ex" "ecution interval PortSet(2,1) Delay(500,mSec) VoltSe(BP_mmHg,1,1,0.184,600) BP_mmHg=BP_mmHg*0.75006 PortSet(2,0) " "" "Clearing" "ETGage" "Replaced" "" "" 22/11/2001 22/11/2001 "Replace ETGage" "" "" "" "Clearing" "Anemometer" "Reprogrammed" "" "" 22/11/2010 22/11/2010 "Corrected program" "Nov. 22, 2010 Corrected the bug on the datalogger program bci_clear20101119kk.CR1. Added a 1 second time dealy in order to allow the bar pressue sensor to warm-up prior to the execution of the reading." "" "" "Clearing" "BP sensor" "Replaced" "G0560091" "A3110002" 22/12/2011 22/12/2011 "Replace Bar Pressure sensor" "Dec. 22, 2011 Sutdown datalogger at 9:45 a.m. Removed Bar Pressure sensor PTB101B - CS105 S/N:A3110002 Installed Bar Pressure sensor PTB110 - CS106 S/N:G0560091 Powered-up datalogger at 10:20" "" "" "Clearing" "Datalogger" "Replaced" "252286 PB30" "36527 PB30" 22/12/2011 22/12/2011 "Replace Data Logger" "Dec. 22, 2011 Sutdown datalogger at 9:45 a.m. Removed datalogger CR1000 S/:36527 PB30 Installed datalogger CR1000 S/N:252286 PB30 with datalogger program: bci_clear20111215kk.CR1 Powered-up datalogger at 10:20" "" "" "Clearing" "ETGage" "Observation" "" "" 23/04/1998 24/04/1998 "Bad data" "" "" "" "Clearing" "ETGage" "Cleaned" "" "" 23/04/2001 23/04/2001 "Replace GorTex covering on ETGage" "Stilling pond was over filled following cleaning. Stablized at correct value ~15:00hr" "" "" "Clearing" "Evaporation Tank" "Installed" "" "" 23/06/1999 23/06/1999 "Install new thermometer in tank. Old thermometer left" "" "" "" "Clearing" "Thermometer" "Replaced" "" "" 23/08/2012 23/08/2012 "Replace Max. temperature thermometer" "" "" "" "Clearing" "Tipping Bucket" "Observation" "" "" 23/11/2010 23/11/2010 "Tipping bucket not working" "" "" "" "Clearing" "RH sensor" "Repaired" "" "" 24/02/1986 26/02/1986 "Repair Relative Humidity sensor" "" "" "" "Clearing" "Anemometer" "Replaced" "" "" 24/05/1994 24/05/1994 "Replace anemometer" "Tipping bucket found plugged with leaves. No idea how long this situation has existed" "" "" "Clearing" "ETGage" "Observation" "" "" 24/05/1996 24/05/1996 "Bad data" "" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 24/05/2011 24/05/2011 "Clean Tipping bucket" "ISCO reading 140mm, manual reading is 148mm" "" "" "Clearing" "Tipping Bucket" "Replaced" "06-287" "10-89" 24/06/2016 24/06/2016 "Replace TB rain gauge" "" "" "" "Clearing" "Datalogger" "Replaced" "35594" "x19475" 24/10/2007 24/10/2007 "Replace Datalogger" "Replace propeller bairings" "" "" "Clearing" "T&H sensor" "Replaced" "z2750040" "" 24/10/2007 24/10/2007 "Replace Temp/Hum sensor" "" "" "" "Clearing" "BP sensor" "Replaced" "z0630032" "p5130011" 24/10/2007 24/10/2007 "Replace Air pressure sensor" "" "" "" "Clearing" "BP sensor" "Replaced" "A3110020" "G0560091" 24/10/2013 24/10/2013 "Replace Bar Pressure Sensor" "October 24, 2013 Logger Shutdown at 8:45 -Removed CS106 PTB110 bar pressure sensor SN:G0560091 -Installed CS105 PTB101B bar pressure sensor SN:A3110020 Logger powerup at 9:10 -Installed the program bci_clear_20131023kk.CR1" "" "" "Clearing" "" "Observation" "" "" 25/03/2006 25/03/2006 "Large branch that was shading the Clearing was cut" "" "" "" "Clearing" "Enclosure" "Replaced" "" "" 25/04/2003 25/04/2003 "Replace Equipment shelter" "" "" "" "Clearing" "Enclosure" "Replaced" "" "" 25/05/2010 25/05/2010 "New Stevenson screen" "May 25, 2010 New Stevenson screen installed at the clearing. The door of the screen was re-oriented towards the North." "" "" "Clearing" "ETGage" "Cleaned" "" "" 25/07/2005 25/07/2005 "Clean both ETGages and replace GorTex coverings" "" "" "" "Clearing" "ETGage" "Observation" "" "" 26/03/1998 26/03/1998 "Bad data" "" "" "" "Clearing" "RH sensor" "Observation" "" "" 26/06/1989 26/06/1989 "Wet-bulb sensor dry" "" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 26/08/2011 26/08/2011 "Clean Tipping bucket" "Thermometers replaced because paint on temperature scale came off." "" "" "Clearing" "ETGage" "Replaced" "" "" 26/11/1993 26/11/1993 "Replace ETGage with different model" "" "" "" "Clearing" "ETGage" "Observation" "" "" 26/12/2001 26/12/2001 "Bad data" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Clearing" "ETGage" "Replaced" "" "" 27/06/1996 27/06/1996 "Replace ETGage in Clearing" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Clearing" "ETGage" "Deactivated" "" "" 27/07/1998 28/07/1998 "Remove ETGage #1" "ETGage #1 showing problems" "" "" "Clearing" "Evaporation Tank" "Installed" "" "" 27/09/1996 27/09/1996 "Installed evaporation tank" "Installed the large, metal evaporation tank to run comparison between tank and ETGages" "" "" "Clearing" "ETGage" "Moved" "" "" 27/09/1996 27/09/1996 "Move ETGage #1 to beside the evaporation tank" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Clearing" "ETGage" "Observation" "" "" 27/09/2005 27/09/2005 "Bad data" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Clearing" "Tipping Bucket" "Cleaned" "" "" 27/10/1999 27/10/1999 "Hobo #3 tipping bucket Cleaned." "" "" "" "Clearing" "Datalogger" "Replaced" "" "" 27/11/1989 27/11/1989 "Replace Datalogger" "" "" "" "Clearing" "ETGage" "Observation" "" "" 27/11/2001 27/11/2001 "Bad data" "" "" "" "Clearing" "ETGage" "Observation" "" "" 27/11/2012 27/11/2012 "Bad data ETGage #1" "" "" "" "Clearing" "Tipping Bucket" "Calibrated" "" "" 28/07/2015 28/07/2015 "Calibrate Tipping bucket" "" "" "" "Clearing" "Datalogger" "Replaced" "" "" 28/11/1988 28/11/1988 "Replace Clearing Datalogger" "" "" "" "Clearing" "Thermometer" "Replaced" "" "" 29/03/2012 29/03/2012 "Replace Max. temperature thermometer" "" "" "" "Clearing" "Enclosure" "Replaced" "" "" 29/10/2014 29/10/2014 "Replace instrument box" "October 29, 2014 Logger shutdown at 9:40 -Installed new instrument box at the clearing -Installed new radio antenna Logger power-up at 12:45" "" "" "Clearing" "Telemetry" "Replaced" "" "" 29/10/2014 29/10/2014 "Replace antenna" "October 29, 2014 Logger shutdown at 9:40 -Installed new radio antenna Logger power-up at 12:45" "" "" "Clearing" "Rain Gauge" "Observation" "" "" 29/12/1989 29/12/1989 "Data lost due to technician error" "" "" "" "Clearing" "Telemetry" "Installed" "" "" 30/06/2008 30/06/2008 "Install radio telemetry system" "Around this date the first radio telemetry system was installed on the Lutz Tower to Lutz1" "" "" "Clearing" "" "Observation" "" "" 30/07/1999 30/07/1999 "Tree cut in Clearing. Station no longer in shadow" "CAL1-dc.prn -> PAR data from Campbell sensorCAL2-dc.prn -> Calibration data from sensors s/n 13588 (#1) & s/n 10456 (#2)" "" "" "Clearing" "ETGage" "Observation" "" "" 30/07/2001 30/07/2001 "Ventilation hole cleaned" "" "" "" "Clearing" "ETGage" "Replaced" "" "" 31/03/1999 31/03/1999 "ETGage #1 replaced (near evaporation pan)" "" "" "" "Clearing" "Air Temp Sensor" "Repaired" "" "" 31/05/1986 31/05/1986 "Fix problem with Air temperature sensor" "" "" "" "Clearing" "Datalogger" "Observation" "" "" 31/05/2010 31/05/2010 "Data logger off-line between 9:30 & 11:40hr" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Clearing" "Rain Gauge" "Cleaned" "" "" 31/12/2014 31/12/2014 "Clean Rain gauges" "It appears that a small piece of metal has broken off of the base of the weir 'V'. This has resulted in the manual ruler measurements being 3-4mm higher than the Radar and Chart recorder" "" "" "Conrad weir" "Tipping Bucket" "Observation" "" "" 01/06/1994 01/06/1994 "Bad data" "" "" "" "Conrad weir" "ISCO" "Repaired" "" "" 03/05/1999 03/05/1999 "Problem fixed" "Level recorded too low" "" "" "Conrad weir" "Tipping Bucket" "Observation" "" "" 03/06/2013 12/06/2013 "Tipping bucket knocked over" "Cutting of trees may have increased the amount of mid-day sun arriving on Clearing Station" "" "" "Conrad weir" "ISCO" "Observation" "" "" 04/01/2012 04/01/2012 "Bubbler tube partially blocked" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Conrad weir" "ISCO" "Cleaned" "" "" 04/01/2012 04/01/2012 "Clean Bubbler tube" "" "" "" "Conrad weir" "Tipping Bucket" "Installed" "" "" 04/04/2011 04/04/2011 "Reinstall Tipping bucket" "" "" "" "Conrad weir" "ISCO" "Observation" "" "" 04/12/2012 04/12/2012 "Battery flat" "Glass tube broken in the morning after morning measurement" "" "" "Conrad weir" "Tipping Bucket" "Discontinued" "" "" 06/01/2014 06/01/2014 "Disconnect Tipping bucket" "When the Conrad weir was built there was a large gap above the weir. Putting a tipping bucket in that location seemed like a good idea. However, over the next 10 years the gap closed. At this point the tipping bucket probably does not 'see' light rain an" "d moderate rains are probably heavily deflected." "" "Conrad weir" "Tipping Bucket" "Repaired" "" "" 06/05/2009 06/05/2009 "Repair Tipping bucket" "Max. temperature observed to be unexpectedly low on June 22 and July 8" "" "" "Conrad weir" "Tipping Bucket" "Observation" "" "" 06/05/2010 07/05/2010 "Tipping bucket registering false tips" "" "" "" "Conrad weir" "ISCO" "Repaired" "" "" 07/10/2009 07/10/2009 "Replace battery charger" "The datalogger was not working during the nights" "" "" "Conrad weir" "ISCO" "Observation" "" "" 07/10/2009 07/10/2009 "Battery giving problems" "" "" "" "Conrad weir" "Tipping Bucket" "Repaired" "" "" 07/11/2013 07/11/2013 "Fix connection" "" "" "" "Conrad weir" "ISCO" "Replaced" "" "" 10/12/2002 10/12/2002 "Replace ISCO" "" "" "" "Conrad weir" "Tipping Bucket" "Moved" "" "" 13/07/1999 13/07/1999 "Move Tipping bucket" "" "" "" "Conrad weir" "ISCO" "Observation" "" "" 13/08/2012 13/08/2012 "Battery flat" "" "" "" "Conrad weir" "ISCO" "Battery Replaced" "" "" 13/08/2012 13/08/2012 "Replace ISCO battery" "" "" "" "Conrad weir" "" "Modified" "" "" 14/08/1997 14/08/1997 "Begin work to level top of weir" "" "" "" "Conrad weir" "ISCO" "Observation" "" "" 14/09/2015 14/09/2015 "ISCO stopped sometime after Sept 14" "" "" "" "Conrad weir" "ISCO" "Observation" "" "" 15/01/2010 28/01/2010 "ISCO not registering precipitation" "Weir cleaned on the 29th. Stilling pond refilled by mid-day on the 30th" "" "" "Conrad weir" "ISCO" "Repaired" "" "" 15/03/2013 15/03/2013 "Batteries 'adjusted'" "" "" "" "Conrad weir" "Tipping Bucket" "Observation" "" "" 16/05/2013 16/05/2013 "Tipping bucket plugged" "" "" "" "Conrad weir" "Tipping Bucket" "Cleaned" "" "" 16/05/2013 16/05/2013 "Clean Tipping bucket" "" "" "" "Conrad weir" "ISCO" "Observation" "" "" 18/01/2012 18/01/2012 "Bubbler tube partially blocked" "Bubbler tube found blocked again. Frecuency of bubbles increased to try to avoid problem in the furture" "" "" "Conrad weir" "Tipping Bucket" "Observation" "" "" 18/06/2013 18/06/2013 "Tipping bucket not registering rainfall" "" "" "" "Conrad weir" "ISCO" "Replaced" "" "" 18/12/2001 18/12/2001 "Replace ISCO with new model" "" "" "" "Conrad weir" "Tipping Bucket" "Observation" "" "" 19/10/1994 19/10/1994 "Bad data" "Tipping bucket blocked with leaves" "" "" "Conrad weir" "ISCO" "Observation" "" "" 21/07/2013 23/07/2013 "ISCO not recording data, bad battery" "" "" "" "Conrad weir" "" "Modified" "" "" 21/10/1997 21/10/1997 "Finish work leveling top of weir" "Top of weir now level +/- 1mm" "" "" "Conrad weir" "Tipping Bucket" "Replaced" "" "" 21/11/2001 21/11/2001 "Replace Tipping bucket" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Conrad weir" "Tipping Bucket" "Observation" "" "" 23/04/2010 10/05/2010 "Tipping bucket registering false tips" "" "" "" "Conrad weir" "Tipping Bucket" "Repaired" "" "" 23/07/2013 23/07/2013 "Repair Tipping bucket connector" "" "" "" "Conrad weir" "Tipping Bucket" "Observation" "" "" 23/10/2013 07/11/2013 "Tipping bucket not working" "" "" "" "Conrad weir" "ISCO" "Observation" "" "" 23/11/2015 23/11/2015 "Continues to have battery problems" "" "" "" "Conrad weir" "ISCO" "Observation" "" "" 24/02/2010 24/02/2010 "ISCO found shut off" "" "" "" "Conrad weir" "" "Modified" "" "" 24/04/1997 24/04/1997 "Increased size of weir (see notes)" "Wings raised in height by 20cm. Extended right wing (looking downstream) at an angle to the original contruction by about 1m (to avoid over topping by high water levels). Rocks removed upstream and downstream from 'V'. Moved copper bubbler tube to imbed" "it into concrete so that it cannot move in the future" "" "Conrad weir" "ISCO" "Observation" "" "" 24/10/2001 24/10/2001 "Lower battery voltage" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Conrad weir" "Tipping Bucket" "Observation" "" "" 24/12/2011 04/01/2012 "Tipping bucket knocked over" "" "" "" "Conrad weir" "ISCO" "Repaired" "" "" 26/03/1997 26/03/1997 "Repositioned bubbler tube" "Corrected problem with data going back at least two months" "" "" "Conrad weir" "ISCO" "Observation" "" "" 26/03/1997 26/03/1997 "Bubbler tube opening above water" "This produced bad data going back at least two months" "" "" "Conrad weir" "Tipping Bucket" "Observation" "" "" 26/04/2000 26/04/2000 "Tipping bucket knocked over" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Conrad weir" "Tipping Bucket" "Replaced" "" "" 26/08/2010 26/08/2010 "Replace Tipping bucket" "Max. temperature unexpectedly low on Aug 30, Sept 7, 8, 27, Nov 18, Dec 1" "" "" "Conrad weir" "ISCO" "Observation" "" "" 27/02/2013 27/02/2013 "Battery flat" "" "" "" "Conrad weir" "Tipping Bucket" "Observation" "" "" 29/02/2012 29/02/2012 "Tipping bucket registered false tips" "Accidental contact with tipping bucket cable produced false tipping events to be registered" "" "" "Conrad weir" "ISCO" "Observation" "" "" 30/04/1999 03/05/1999 "Data bad" "" "" "" "Lutz 10m" "T&H sensor" "Replaced" "" "" 05/03/1998 05/03/1998 "Replace Temp/Hum sensor" "" "" "" "Lutz 10m" "Air Temp Sensor" "Installed" "" "" 14/06/1989 15/06/1989 "Install electronic air temperature sensor" "" "" "" "Lutz 10m" "T&H sensor" "Replaced" "" "" 14/07/1998 14/07/1998 "Replace Temp/Hum sensor" "Sensor replaced with one with a shorter cable" "" "" "Lutz 10m" "T&H sensor" "Observation" "" "" 17/02/1999 17/02/1999 "Sensor readings doubtful during heavy rains" "Cleaned at 9:25hr" "" "" "Lutz 10m" "T&H sensor" "Replaced" "" "" 19/07/2001 19/07/2001 "Replace Temp/Hum sensor" "Temperature data bad" "" "" "Lutz 10m" "T&H sensor" "Installed" "" "" 25/03/1997 25/03/1997 "Install Vaisal Temp/Hum sensor" "" "" "" "Lutz 10m" "Air Temp Sensor" "Installed" "" "" 25/09/1991 25/09/1991 "Reinstall Air temperature sensor" "Reinstallation finished at ~9:35hr" "" "" "Lutz 1m" "Air Temp Sensor" "Observation" "" "" 01/07/1986 01/07/1986 "Not working" "" "" "" "Lutz 1m" "Air Temp Sensor" "Replaced" "" "" 01/07/1986 01/07/1986 "Replace Air temperature sensor" "" "" "" "Lutz 1m" "Datalogger" "Replaced" "" "" 02/02/1987 02/02/1987 "Replace Datapod" "" "" "" "Lutz 1m" "T&H sensor" "Modified" "" "" 02/07/2013 02/07/2013 "Replace radiation shield" "" "" "" "Lutz 1m" "Air Temp Sensor" "Installed" "" "" 02/11/1985 02/11/1985 "Install new Temperature sensor" "" "" "" "Lutz 1m" "ETGage" "Replaced" "" "" 03/03/2010 03/03/2010 "Shield Replacement" "BCI_LUTZ2 1meter Shield. The shield was replaced by a clean and identical shield - 6 gill RM Young" "" "" "Lutz 1m" "Datalogger" "Replaced" "" "" 04/02/1987 04/02/1987 "Replace Datapod" "Replaced datalogger again because it wasn't working" "" "" "Lutz 1m" "Thermometer" "Repaired" "" "" 04/04/2014 04/04/2014 "Adjusted scale - was reading 1C too low" "" "" "" "Lutz 1m" "Psychrometer" "Replaced" "" "" 05/03/2004 11/11/2004 "Replace Psychrometer after old one broke" "" "" "" "Lutz 1m" "Thermometer" "Replaced" "" "" 06/07/2010 06/07/2010 "Replace Max/Min thermometers" "Thermometers replaced because paint on temperature scale came off." "" "" "Lutz 1m" "Thermometer" "Installed" "" "" 06/10/2011 06/10/2011 "Reinstall Max/Min 'U' thermometers" "Thermometers replaced because paint on temperature scale came off." "" "" "Lutz 1m" "Air Temp Sensor" "Replaced" "" "" 06/12/1989 06/12/1989 "Replace Air temperature sensor" "" "" "" "Lutz 1m" "T&H sensor" "Chip Replaced" "" "" 07/02/2013 07/02/2013 "Change T&H sensor chip" "Feb. 7th, 2013 Logger Shutdown at 9:27 -Installed new chip on CS215 T&RH @ 1m - old chip giving" "NAN" " readings for air temp. Logger power-up at 11:11""" "Lutz 1m" "Thermometer" "Discontinued" "" "" 07/11/1990 07/11/1990 "Additional thermometer moved to 42m" "" "" "" "Lutz 1m" "T&H sensor" "Observation" "" "" 08/01/1999 08/01/1999 "Sensor readings doubtful during heavy rains" "Water trapped in funnel allowed to enter tipping bucket after cleaning at 10:20hr" "" "" "Lutz 1m" "Enclosure" "Replaced" "" "" 08/06/2010 08/06/2010 "New Stevenson screen" "June 8, 2010 New Stevenson screen installed at the base of the Lutz tower" "" "" "Lutz 1m" "Psychrometer" "Replaced" "" "" 09/09/2013 09/09/2013 "Replace Psychrometer after old one broke" "" "" "" "Lutz 1m" "Air Temp Sensor" "Moved" "" "" 09/11/1990 09/11/1990 "Sensor moved to same level as max/min thermometer" "" "" "" "Lutz 1m" "Thermometer" "Replaced" "" "" 09/11/2010 09/11/2010 "Replace Max/Min thermometers" "Thermometers replaced because paint on temperature scale came off." "" "" "Lutz 1m" "Enclosure" "Replace shield" "" "" 10/10/2014 10/10/2014 "Replace Instrument enclosure" "" "" "" "Lutz 1m" "Psychrometer" "Replaced" "" "" 10/11/1994 10/11/1994 "Replace Pyschrometer" "Thermometer broke on New pyschrometer. Now using old psychrometer. Units now in F" "" "" "Lutz 1m" "T&H sensor" "Installed" "" "" 12/12/1991 12/12/1991 "Install Temp/Hum sensor" "Raul says that the original Temperature sensor was left in place for 'some time'" "" "" "Lutz 1m" "Air Temp Sensor" "Observation" "" "" 13/11/1989 13/11/1989 "Air temperature sensor damaged" "" "" "" "Lutz 1m" "Thermometer" "Observation" "" "" 14/03/1997 14/03/1997 "Questionable minimum temp. reading" "" "" "" "Lutz 1m" "ETGage" "Cleaned" "" "" 14/08/2013 14/08/2013 "Clean ETGage and replace GorTex covering" "" "" "" "Lutz 1m" "Psychrometer" "Replaced" "" "" 15/07/2005 15/07/2005 "Replace Psychrometer after old one broke" "" "" "" "Lutz 1m" "T&H sensor" "Replaced" "" "" 15/12/1992 15/12/1992 "Replace Rotronic T&H sensor" "" "" "" "Lutz 1m" "Psychrometer" "Replaced" "" "" 15/12/2004 15/12/2004 "Replace Psychrometer after old one broke" "" "" "" "Lutz 1m" "Thermometer" "Replaced" "" "" 15/12/2014 15/12/2014 "Replace Max. thermometer" "" "" "" "Lutz 1m" "Enclosure" "Replace shield" "" "" 16/05/2011 16/05/2011 "Replace Termp/Hum radiation shield with new model" "Temp/Humdity radiation shield changed for new model @ ~11:50hr" "" "" "Lutz 1m" "Thermometer" "Replaced" "" "" 16/06/2010 16/06/2010 "Replace Max/Min thermometers with new model" "" "" "" "Lutz 1m" "T&H sensor" "Calibrated" "" "" 17/04/2009 17/04/2009 "Calibrate Temp&hum sensor against sling psychrometer" "" "" "" "Lutz 1m" "Thermometer" "Installed" "" "" 17/10/1990 17/10/1990 "Additional Max/Min thermometer installed" "" "" "" "Lutz 1m" "T&H sensor" "Chip Replaced" "EE3022" "" 17/10/2012 17/10/2012 "Change T&H sensor chip" "October 17, 2012 Replaced the T&RH chip at 1m - Lutz Tower Logger shutdown at 9:31am -Replaced sensor chip - pernament sensor CS215 SN EE3022 Logger powered-up at 9:37am" "" "" "Lutz 1m" "T&H sensor" "Observation" "" "" 17/11/1992 18/11/1992 "Rotronic T&H sensor not working" "Tipping bucket not recording data" "" "" "Lutz 1m" "T&H sensor" "Deactivated" "" "" 17/11/1992 17/11/1992 "Disconnect the T&H sensor" "" "" "" "Lutz 1m" "Air Temp Sensor" "Repaired" "" "" 18/06/1986 18/06/1986 "Fix Temperature sensor" "" "" "" "Lutz 1m" "Psychrometer" "Replaced" "" "" 18/08/1994 18/08/1994 "Replace Pyschrometer" "New pyschrometer. Units now in Celcius" "" "" "Lutz 1m" "T&H sensor" "Replaced" "" "" 18/09/2008 18/09/2008 "Replace T&H sensor with new model" "September 18, 2008 Installed CS215 sensor at 1m" "" "" "Lutz 1m" "T&H sensor" "Misc" "" "" 18/11/1992 18/11/1992 "Reconnect the T&H sensor" "" "" "" "Lutz 1m" "T&H sensor" "Replaced" "" "" 18/12/2001 18/12/2001 "Replace Temp/Hum sensor" "" "" "" "Lutz 1m" "ETGage" "Cleaned" "" "" 19/06/2014 19/06/2014 "Clean ETGage and replace GorTex covering" "" "" "" "Lutz 1m" "Psychrometer" "Replaced" "" "" 20/04/2015 20/04/2015 "Replace Psychrometer after old one broke" "" "" "" "Lutz 1m" "T&H sensor" "Chip Replaced" "" "" 20/10/2010 20/10/2010 "Change T&H sensor chip" "October 20, 2010 Replaced the T&RH Chip at 1m. No data collected between 2010-10-20 10:00 and 2010-10-20 14:00" "" "" "Lutz 1m" "Air Temp Sensor" "Replaced" "" "" 22/11/1989 22/11/1989 "Replace Air temperature sensor" "" "" "" "Lutz 1m" "T&H sensor" "Replaced" "" "" 23/07/2001 23/07/2001 "Replace Temp/Hum sensor" "" "" "" "Lutz 1m" "T&H sensor" "Observation" "" "" 23/07/2001 23/07/2001 "Temp/Hum sensor not working" "" "" "" "Lutz 1m" "Air Temp Sensor" "Replaced" "" "" 24/07/1990 24/07/1990 "Replace Air temperature sensor" "" "" "" "Lutz 1m" "Datalogger" "Replaced" "" "" 25/01/1990 25/01/1990 "Replace datalogger" "Battery in datalogger exploded. Datalogger cleaned, batteries replaced. Exact date not specified" "" "" "Lutz 1m" "T&H sensor" "Repaired" "" "" 26/07/2001 26/07/2001 "Fix Temp/Hum sensor" "Humidity may be 4-5% too high when compared to the other tower sensors" "" "" "Lutz 1m" "T&H sensor" "Chip Replaced" "" "" 26/08/2013 26/08/2013 "Change T&H sensor chip" "August 26, 2013 Logger shutdow at 11:25am -Replaced the chip of CS215 T&RH sensor at Lutz tower 1m - old chip giving NAN -The NAN problem was reported in Feb.2013 - the chip was replaced in Feb. 2013 -The problem is recurring, it may indicate that th" "e sensor has a problem. Logger power-up at 11:40am" "" "Lutz 1m" "T&H sensor" "Replaced" "E10782" "E3023" 27/11/2014 27/11/2014 "Replaced T&RH Sensor" "Nov 27th, 2014 The 1m CS215 T&RH sensor failed on Nov 24, 2014 at 17:45 Logger shutdown on Nov 27 at 9:10 am -Removed 1m CS215 T&RH sensor SN:EE3023 -Installed new CS215 T&RH sensor SN:10782" "" "" "Lutz 1m" "T&H sensor" "Replaced" "" "" 29/05/1999 29/05/1999 "Replace Temp/Hum sensor" "" "" "" "Lutz 1m" "T&H sensor" "Replaced" "" "" 29/06/1999 29/06/1999 "Replace Temp/Hum sensor" "It was very dirty" "" "" "Lutz 1m" "Air Temp Sensor" "Replaced" "" "" 29/08/1990 29/08/1990 "Replace Air temperature sensor" "" "" "" "Lutz 1m" "Thermometer" "Replaced" "" "" 30/04/1992 30/04/1992 "Replace Max/Min thermometer" "" "" "" "Lutz 1m" "Datalogger" "Replaced" "" "" 30/06/2008 30/06/2008 "Replace Lutz1 datalogger" "Around this date the first radio telemetry system was installed in the Clearing" "" "" "Lutz 20m" "T&H sensor" "Replaced" "" "" 01/04/1999 01/04/1999 "Replace Temp/Hum sensor" "" "" "" "Lutz 20m" "T&H sensor" "Modified" "" "" 02/07/2013 02/07/2013 "Replace radiation shield" "" "" "" "Lutz 20m" "Datalogger" "Repaired" "" "" 05/02/1990 05/02/1990 "Replace batteries in datalogger" "" "" "" "Lutz 20m" "Psychrometer" "Replaced" "" "" 05/03/2004 05/03/2004 "Replace Psychrometer after old one broke" "" "" "" "Lutz 20m" "T&H sensor" "Replaced" "" "" 05/06/1992 05/06/1992 "Replace Temp/Hum sensor" "Needed to replace the sensor because the cable had been chewed by some animal" "" "" "Lutz 20m" "T&H sensor" "Chip Replaced" "E2899" "" 07/08/2013 07/08/2013 "Change T&H sensor chip" "August 7, 2013 Logger shutdown at 11:30am -Repleced CS215 T&RH chip at the 20m sensor. CS215 sensor SN:E2899 Logger power up at 11:58am" "" "" "Lutz 20m" "T&H sensor" "Observation" "" "" 08/07/1999 08/07/1999 "Temp/Hum sensor seems to not be working" "Probably damaged in lightning strike" "" "" "Lutz 20m" "Air Temp Sensor" "Repaired" "" "" 09/07/1990 09/07/1990 "Air temperature sensor not properly connected to datalogger" "" "" "" "Lutz 20m" "Psychrometer" "Replaced" "" "" 09/09/2013 09/09/2013 "Replace Psychrometer after old one broke" "" "" "" "Lutz 20m" "Psychrometer" "Replaced" "" "" 10/11/1994 10/11/1994 "Replace Pyschrometer" "Thermometer broke on New pyschrometer. Now using old psychrometer. Units now in F" "" "" "Lutz 20m" "T&H sensor" "Replaced" "" "" 10/12/1992 10/12/1992 "Replace Rotronic T&H sensor" "" "" "" "Lutz 20m" "T&H sensor" "Replaced" "" "" 11/04/2005 11/04/2005 "Replace Temp/Hum sensor" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 20m" "T&H sensor" "Chip Replaced" "" "" 11/07/2011 11/07/2011 "Change T&H sensor chip" "July 11, 2011 Logger shutdown at 10:07 - Installed new CS 215 chip at 20m Logger powered up at 12:10" "" "" "Lutz 20m" "T&H sensor" "Modified" "" "" 12/03/2012 12/03/2012 "Replace radiation shield @ 10:40hr" "" "" "" "Lutz 20m" "T&H sensor" "Replaced" "E12916" "E2899" 12/08/2015 12/08/2015 "Changed 20m T&RH sensors" "August 12, 2015 Logger Shutdown Lutz2 @ 8:57 am -Removed 20m T&RH CS215 SN:EE2889 -INstalled 20 T&RH CS215 SN:E12916 Logger power-up Lutz2 @10:30 Shutdown by mistake Lutz1 @ 9:22, Lutz1 logger res-started at 9:56" "" "" "Lutz 20m" "Air Temp Sensor" "Installed" "" "" 14/06/1989 14/06/1989 "Install electronic air temperature sensor" "" "" "" "Lutz 20m" "Psychrometer" "Replaced" "" "" 15/07/2005 15/07/2005 "Replace Psychrometer after old one broke" "" "" "" "Lutz 20m" "Psychrometer" "Replaced" "" "" 15/12/2004 15/12/2004 "Replace Psychrometer after old one broke" "" "" "" "Lutz 20m" "T&H sensor" "Replace shield" "" "" 17/03/2010 17/03/2010 "Shield Replacement" "BCI_LUTZ2 20meter Shield. The shield was replaced by a clean and identical shield - 12 gill RM Young" "" "" "Lutz 20m" "T&H sensor" "Calibrated" "" "" 17/04/2009 17/04/2009 "Calibrate Temp&hum sensor against sling psychrometer" "Hour Dry Bulb Wet Bulb10:30 32.0 25.0" "" "" "Lutz 20m" "T&H sensor" "Replaced" "" "" 17/05/1993 17/05/1993 "Replace Rotronic T&H sensor" "Sensor moved inside of the shelter. The same place as the Rotronic T&H sensor.No indication of when it was moved out after the 5th of May." "" "" "Lutz 20m" "Psychrometer" "Replaced" "" "" 18/08/1994 18/08/1994 "Replace Pyschrometer" "New pyschrometer. Units now in Celcius" "" "" "Lutz 20m" "T&H sensor" "Replaced" "" "" 18/12/2001 18/12/2001 "Replace Temp/Hum sensor" "" "" "" "Lutz 20m" "T&H sensor" "Replaced" "" "" 19/01/2005 19/01/2005 "Replace Sensor head on Temp/Hum sensor" "" "" "" "Lutz 20m" "Psychrometer" "Replaced" "" "" 20/04/2015 20/04/2015 "Replace Psychrometer after old one broke" "" "" "" "Lutz 20m" "T&H sensor" "Installed" "" "" 21/02/1992 21/02/1992 "Install Temp/Hum sensor" "Battery went bad at ~16:00hr. Data bad until Feb 28 @ 9:15hr" "" "" "Lutz 20m" "Air Temp Sensor" "Observation" "" "" 21/11/1989 21/11/1989 "Air temperature sensor probably damaged" "" "" "" "Lutz 20m" "T&H sensor" "Replaced" "E2899" "Z3810012" 22/07/2009 22/07/2009 "Replace T&H sensor with new model" "July 22, 2009 Installed CS215 Temp&RH sensor at 20m, S/N E2899 Removed HMP45C T&RH sensor at 20m, S/N Y3250082 - Vaisala S/N Z3810012" "" "" "Lutz 20m" "Air Temp Sensor" "Moved" "" "" 23/02/1993 23/02/1993 "Move sensor to inside of shelter" "" "" "" "Lutz 20m" "T&H sensor" "Replaced" "" "" 24/01/2001 24/01/2001 "Replace Temp/Hum sensor with new model" "Install Vaisala model HMP 45C" "" "" "Lutz 20m" "T&H sensor" "Observation" "" "" 25/03/1993 17/05/1993 "Bad data" "Beginning on the 25th, the Rotronic T&H data is bad" "" "" "Lutz 20m" "T&H sensor" "Calibrated" "" "" 26/07/1993 29/07/1993 "Calibrate Air temperature sensor" "Rotronic T&H sensor was installed between the 26th and 29th in order to compare the data with the LiCor air temperature sensor" "" "" "Lutz 20m" "Air Temp Sensor" "Observation" "" "" 27/11/1989 27/11/1989 "Air temperature sensor damaged" "" "" "" "Lutz 30m" "Air Temp Sensor" "Replaced" "" "" 02/05/1990 02/05/1990 "Replace Air temperature sensor" "" "" "" "Lutz 30m" "Air Temp Sensor" "Repaired" "" "" 09/07/1990 09/07/1990 "Air temperature sensor not properly connected to datalogger" "" "" "" "Lutz 30m" "Air Temp Sensor" "Observation" "" "" 16/09/1991 16/09/1991 "Air temperature sensor found not connected" "" "" "" "Lutz 30m" "Air Temp Sensor" "Repaired" "" "" 16/09/1991 16/09/1991 "Repair Air temperature sensor" "" "" "" "Lutz 30m" "T&H sensor" "Replaced" "" "" 19/07/2001 19/07/2001 "Replace Temp/Hum sensor" "" "" "" "Lutz 30m" "T&H sensor" "Installed" "" "" 25/03/1997 25/03/1997 "Install Vaisal Temp/Hum sensor" "" "" "" "Lutz 30m" "T&H sensor" "Observation" "" "" 31/08/1998 31/08/1998 "Questionable data" "" "" "" "Lutz 42m" "Datalogger" "Battery Replaced" "" "" 01/01/1990 01/01/1990 "Replace Battery of datalogger" "Correct water level reestablished at 12:29hr" "" "" "Lutz 42m" "Anemometer" "Replaced" "" "" 01/01/1990 01/01/1990 "Replace Anemometer" "Replace anemometer because the data were bad" "" "" "Lutz 42m" "ISCO" "Observation" "" "" 01/03/1996 08/03/1996 "Bad data" "" "" "" "Lutz 42m" "Datalogger" "Observation" "" "" 02/06/1999 02/06/1999 "Lutz tower Datalogger was damaged and data lost" "Level recorded too low between April 30 @ ~16:00hr and May 3 @ ~10:40hr" "" "" "Lutz 42m" "T&H sensor" "Modified" "" "" 02/07/2013 02/07/2013 "Replace radiation shield" "" "" "" "Lutz 42m" "Totalizing Anemometer" "Installed" "" "" 02/11/1988 02/11/1988 "Install Totalizing Anemometer on tower" "" "" "" "Lutz 42m" "PAR sensor" "Calibrated" "" "" 02/12/1998 02/12/1998 "Calibrate PAR against two other sensors" "" "" "" "Lutz 42m" "Pyranometer" "Battery Replaced" "" "" 03/02/1993 03/02/1993 "Replace datalogger battery. Several hours of data lost" "" "" "" "Lutz 42m" "PAR sensor" "Battery Replaced" "" "" 03/02/1993 03/02/1993 "Replace datalogger battery. Several hours of data lost" "Block terminal on datalogger loose. Bad data between June 10, ~9:00hr and June 11, ~10:00hr Calibration data available for missing values" "" "" "Lutz 42m" "Anemometer" "Calibrated" "" "" 03/02/1999 03/02/1999 "Recalibrate Anemometer" "" "" "" "Lutz 42m" "T&H sensor" "Observation" "" "" 03/03/1993 03/03/1993 "Several hours of data lost" "Someone touched the T&H datalogger which cuased it to change its configuration resulting in the lose of several hours of data." "" "" "Lutz 42m" "Thermometer" "Observation" "" "" 03/03/1993 03/03/1993 "Data lost" "Someone touched the Max/Min thermometer which may have altered the max. temperature." "" "" "Lutz 42m" "Anemometer" "Calibrated" "" "" 03/03/2000 03/03/2000 "Calibrate Anemometer" "" "" "" "Lutz 42m" "Thermometer" "Replaced" "" "" 03/03/2015 03/03/2015 "Replace 'U' thermometer - mercury split on old thermometer" "" "" "" "Lutz 42m" "Pyranometer" "Replaced" "" "" 03/07/1990 03/07/1990 "Replace Pyranometer" "" "" "" "Lutz 42m" "PAR sensor" "Replaced" "" "" 03/07/1990 03/07/1990 "Replace PAR sensor" "" "" "" "Lutz 42m" "Totalizing Anemometer" "Installed" "" "" 03/07/1991 03/07/1991 "Install Totalizing anemometer" "Sensor repaired at ~9:15hr. Sensors at 20m & 42m offline for a few minutes to reconnect sensor." "" "" "Lutz 42m" "ETGage" "Repaired" "" "" 03/12/2012 03/12/2012 "Repair ETGage" "" "" "" "Lutz 42m" "PAR sensor" "Calibrated" "" "" 04/02/1999 04/02/1999 "Calibrate PAR sensor" "CAL1-dc.prn -> PAR data from Vaisala sensor" "" "" "Lutz 42m" "T&H sensor" "Observation" "" "" 04/03/1992 04/03/1992 "Battery on datalogger drained" "" "" "" "Lutz 42m" "Anemometer" "Observation" "" "" 04/03/1992 04/03/1992 "Battery on datalogger drained" "" "" "" "Lutz 42m" "Net Radiometer" "Observation" "" "" 04/06/1997 04/06/1997 "Dome over sensor broken by birds" "This device was installed, but the device was later abandoned because birds attacked the sensor dome" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 04/06/2001 04/06/2001 "ETGage broken" "" "" "" "Lutz 42m" "T&H sensor" "Chip Replaced" "" "" 04/08/2011 04/08/2011 "Change T&H sensor chip" "August 4, 2011 Data logger shutdown at 11:56 Replaced sensirion chip for T&RH - CS215 sensor at 42m Data logger powered-up at 12:12" "" "" "Lutz 42m" "Tipping Bucket" "Replaced" "" "" 04/12/1990 04/12/1990 "Replace Tipping bucket with new one" "" "" "" "Lutz 42m" "Totalizing Anemometer" "Deactivated" "" "" 04/12/2006 11/12/2006 "Totalizing anemometer taken down for repairs" "Anemometer taken down on the 16th and reinstalled on the 17th following repairs" "" "" "Lutz 42m" "PAR sensor" "Calibrated" "" "" 05/03/1998 05/03/1998 "Calibrate PAR sensor" "Replace with new CR10x @ ~10:30hr" "" "" "Lutz 42m" "Psychrometer" "Replaced" "" "" 05/03/2004 05/03/2004 "Replace Psychrometer after old one broke" "" "" "" "Lutz 42m" "Air Temp Sensor" "Moved" "" "" 05/05/1993 05/05/1993 "Move sensor to inside of shelter" "" "" "" "Lutz 42m" "Thermometer" "Replaced" "" "" 05/05/2014 05/05/2014 "Replace 'U' thermometer" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 42m" "PAR sensor" "Replaced" "" "" 05/11/1993 05/11/1993 "Replace PAR sensor" "" "" "" "Lutz 42m" "Pyranometer" "Moved" "" "" 05/12/1997 05/12/1997 "Move Pyranometers to support arm on south side of tower" "" "" "" "Lutz 42m" "Pyranometer" "Reprogrammed" "" "" 05/12/1997 05/12/1997 "Change program to correct errors with pyranometer data" "Old sensor producing bad data" "" "" "Lutz 42m" "PAR sensor" "Reprogrammed" "" "" 05/12/1997 05/12/1997 "Change program to correct errors with PAR data" "" "" "" "Lutz 42m" "ISCO" "Repaired" "" "" 06/01/1997 06/01/1997 "Adjust ISCO calibration to match true values" "ISCO was reading 20mm too high" "" "" "Lutz 42m" "Totalizing Anemometer" "Observation" "" "" 06/03/1992 06/03/1992 "Totalizing anemometer not working well" "" "" "" "Lutz 42m" "Totalizing Anemometer" "Replaced" "" "" 06/03/1992 06/03/1992 "Replace Totalizing anemometer" "" "" "" "Lutz 42m" "Anemometer" "Repaired" "" "" 06/05/1988 06/05/1988 "Adjusted Vaisala anemometer to match datalogger" "" "" "" "Lutz 42m" "Anemometer" "Replaced" "" "" 06/05/1999 06/05/1999 "Replace Anemometer" "Cleaned at 9:25hr" "" "" "Lutz 42m" "PAR sensor" "Calibrated" "" "" 06/06/2000 06/06/2000 "Calibrate PAR sensor" "" "" "" "Lutz 42m" "ETGage" "Battery Replaced" "" "" 06/09/1995 06/09/1995 "Replace ETGage battery" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 42m" "Totalizing Anemometer" "Observation" "" "" 07/01/1991 07/01/1991 "Totalizing anemometer not working properly" "Clock replaced. Working properly at 10:24hr" "" "" "Lutz 42m" "PAR sensor" "Calibrated" "" "" 07/01/1999 07/01/1999 "Calibrate PAR sensor" "" "" "" "Lutz 42m" "T&H sensor" "Replaced" "" "" 07/02/2007 07/02/2007 "Replace Temp/Hum sensor" "Replacement may have happened anytime between Feb 5 & 9" "" "" "Lutz 42m" "T&H sensor" "Replaced" "E3988" "E4058" 07/02/2013 07/02/2013 "Replace T&H sensor" "Feb. 7th, 2013 Logger Shutdown at 9:27 -Removed 42m T&RH CS215, SN:E4058 -Installed 42m T&RH CS215, SNE3988 Logger power-up at 11:11" "" "" "Lutz 42m" "Anemometer" "Moved" "" "" 07/04/1988 07/04/1988 "Adjust position of Anemometer" "" "" "" "Lutz 42m" "Thermometer" "Installed" "" "" 07/11/1990 07/11/1990 "Install thermometer" "" "" "" "Lutz 42m" "T&H sensor" "Observation" "" "" 07/12/1992 07/12/1992 "Rotronic T&H sensor temporarily diconnected" "" "" "" "Lutz 42m" "Enclosure" "Replace shield" "" "" 07/12/1992 07/12/1992 "Replace instrument shelter" "Block terminal on datalogger loose. Bad data between June 10, ~9:00hr and June 11, ~10:00hr Calibration data available for missing values" "" "" "Lutz 42m" "Thermometer" "Replaced" "" "" 08/02/1989 08/02/1989 "Install Max/Min thermometer" "" "" "" "Lutz 42m" "Datalogger" "Reprogrammed" "" "" 08/02/1999 08/02/1999 "Reprogram datalogger to correct problem with PAR" "" "" "" "Lutz 42m" "PAR sensor" "Observation" "" "" 08/02/1999 08/02/1999 "PAR data bad" "" "" "" "Lutz 42m" "ISCO" "Repaired" "" "" 08/03/1996 08/03/1996 "Adjust ISCO calibration to match true values" "ISCO registering too high" "" "" "Lutz 42m" "ETGage" "Replaced" "" "" 08/07/1996 08/07/1996 "Replace ETGage in Clearing" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 42m" "Totalizing Anemometer" "Installed" "" "" 08/10/2001 08/10/2001 "Install Totalizing anemometer at 42m" "" "" "" "Lutz 42m" "Pyranometer" "Replaced" "" "" 09/01/1989 09/01/1989 "Replace Pyranometer" "" "" "" "Lutz 42m" "PAR sensor" "Replaced" "" "" 09/01/1989 09/01/1989 "Replace PAR sensor" "" "" "" "Lutz 42m" "PAR sensor" "Calibrated" "" "" 09/04/1992 09/04/1992 "Calibrate PAR sensor" "Max. temperatures before the 30th should be increased by 1 degree. Minimum temperatures are okay." "" "" "Lutz 42m" "ETGage" "Observation" "" "" 09/06/1995 09/06/1995 "Bad data" "Probably bad datum after heavy rain (this eventually turned out to be a problem of water getting inside of the device)" "" "" "Lutz 42m" "Datalogger" "Reprogrammed" "" "" 09/07/2012 09/07/2012 "Convert to MySQL" "July 9th, 2012 The BCI Lutz2 datalogger was converted to MySQL. Loaded the program bci_lutz2_20120709kk.CR1 The program was uploaded at 18:00 The program has the following imput locations..." "TIMESTAMP" ", "RECORD", "PBID", "BattV_Avg", "AirTC_01m_MAX", "A""" "Lutz 42m" "Psychrometer" "Replaced" "" "" 09/09/2013 09/09/2013 "Replace Psychrometer after old one broke" "" "" "" "Lutz 42m" "ETGage" "Cleaned" "" "" 10/04/2012 10/04/2012 "Clean ETGage and replace GorTex covering" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 10/05/1995 10/05/1995 "Bad data" "Probably bad datum after heavy rain (this eventually turned out to be a problem of water getting inside of the device)" "" "" "Lutz 42m" "Pyranometer" "Observation" "" "" 10/06/1992 11/06/1992 "Connection problem caused bad data" "Block terminal on datalogger loose. Bad data between June 10, ~9:00hr and June 11, ~10:00hr Calibration data available for missing values" "" "" "Lutz 42m" "PAR sensor" "Observation" "" "" 10/06/1992 11/06/1992 "Connection problem caused bad data" "Block terminal on datalogger loose. Bad data between June 10, ~9:00hr and June 11, ~10:00hr Calibration data available for missing values" "" "" "Lutz 42m" "Datalogger" "Reprogrammed" "" "" 10/07/2012 10/07/2012 "Adjust datalogger program" "July 10th, 2012 @ 15:00 There was an adjustment to the datalogger program - the imput locations' names for 42m were properly named by using the 42m designation instead of 40m - the new logger program is bci_Lutz2_20120710kk.CR1 Imput locations' names fo" "r this new program..." "TIMESTAMP" "Lutz 42m" "RH sensor" "Observation" "" "" 10/08/1992 14/10/1992 "Sensor damaged" "" "" "" "Lutz 42m" "Psychrometer" "Replaced" "" "" 10/11/1994 10/11/1994 "Replace Pyschrometer" "Thermometer broke on New pyschrometer. Now using old psychrometer. Units now in F" "" "" "Lutz 42m" "Anemometer" "Replaced" "" "" 10/12/1987 10/12/1987 "Replace Anemometer" "The hour on the anemometer continues to shift foreward despite having changed the batteries" "" "" "Lutz 42m" "ISCO" "Observation" "" "" 11/03/1996 18/03/1996 "Bad data" "ISCO registering too high" "" "" "Lutz 42m" "Pyranometer" "Repaired" "" "" 11/06/1992 11/06/1992 "Repair connection to datalogger" "Block terminal on datalogger loose. Bad data between June 10, ~9:00hr and June 11, ~10:00hr Calibration data available for missing values" "" "" "Lutz 42m" "PAR sensor" "Repaired" "" "" 11/06/1992 11/06/1992 "Repair connection to datalogger" "Block terminal on datalogger loose. Bad data between June 10, ~9:00hr and June 11, ~10:00hr Calibration data available for missing values" "" "" "Lutz 42m" "T&H sensor" "Chip Replaced" "" "" 11/07/2011 11/07/2011 "Change T&H sensor chip" "July 11, 2011 Logger shutdown at 10:07 - Installed new CS 215 chip at 42m - Noticed that the new 42m chip was reading high - replaced this chip at 11:47 Logger powered up at 10:28 Logger shutdown at 11:47 - Given that the new chip installed at 42m was r" "eading high, the old chip from 20m was installed at 42m - A new chip will be sent to Raul for installation at 42m Logger powered up at 12:10" "" "Lutz 42m" "ETGage" "Replaced" "" "" 11/09/1995 11/09/1995 "Replace ETGage" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 11/09/1996 11/09/1996 "Bad data" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 42m" "Totalizing Anemometer" "Repaired" "" "" 11/12/2006 11/12/2006 "Repair Totalizing anemometer" "Anemometer taken down on the 16th and reinstalled on the 17th following repairs" "" "" "Lutz 42m" "Net Radiometer" "Installed" "" "" 12/05/1997 12/05/1997 "Install Net Radiometer" "This device was installed, but the device was later abandoned because birds attacked the sensor dome" "" "" "Lutz 42m" "Air Temp Sensor" "Observation" "" "" 12/08/1991 12/08/1991 "Air temperature sensor found not connected" "" "" "" "Lutz 42m" "Air Temp Sensor" "Repaired" "" "" 12/08/1991 12/08/1991 "Repair Air temperature sensor" "" "" "" "Lutz 42m" "T&H sensor" "Replaced" "E12902" "E3998" 12/08/2015 12/08/2015 "Changed 42m T&RH sensors" "August 12, 2015 Logger Shutdown Lutz2 @ 8:57 am -Removed 42m T&RH CS215 SN:E3998 -Installed 42m T&RN CS215 SN:E12902 Logger power-up Lutz2 @10:30 Shutdown by mistake Lutz1 @ 9:22, Lutz1 logger res-started at 9:56" "" "" "Lutz 42m" "PAR sensor" "Observation" "" "" 12/11/1999 12/11/1999 "Data logger stopped & some data lost" "" "" "" "Lutz 42m" "Anemometer" "Deactivated" "" "" 13/06/1988 13/06/1988 "Send Vaisla Anemometer for repairs" "" "" "" "Lutz 42m" "Anemometer" "Repaired" "" "" 13/06/1991 13/06/1991 "Replace batteries on Anemometer" "" "" "" "Lutz 42m" "ISCO" "Observation" "" "" 13/06/1995 21/06/1995 "ISCO giving data 12mm higher than measured manually" "ISCO registering 169mm while manual reading is 157mm" "" "" "Lutz 42m" "ETGage" "Cleaned" "" "" 13/10/2015 13/10/2015 "Clean ETGage" "" "" "" "Lutz 42m" "ETGage" "Replaced" "" "" 13/12/1993 14/12/1993 "Replace ETGage with different model" "Replace manual ETGage with electroinc version around 10-11:00hr" "" "" "Lutz 42m" "Anemometer" "Replaced" "" "" 13/12/1993 13/12/1993 "Replace anemometer" "Installed ETGage on tower again, however, the sensor is not producing data." "" "" "Lutz 42m" "ETGage" "Installed" "" "" 13/12/1993 13/12/1993 "Install ETGage on tower again" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 13/12/1993 28/02/1994 "Bad data" "ET from Clearing lower than expected. Readings made properly." "" "" "Lutz 42m" "Anemometer" "Observation" "" "" 14/05/1990 14/05/1990 "Anemometer broken" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 14/06/2000 14/06/2000 "Bad data" "" "" "" "Lutz 42m" "T&H sensor" "Replaced" "" "" 14/07/1998 14/07/1998 "Replace Temp/Hum sensor" "Sensor replaced with sensor formerly at 10m" "" "" "Lutz 42m" "Net Radiometer" "Discontinued" "" "" 14/07/1998 14/07/1998 "Remove Net Radiometer" "16-oct-1998, ~8:50hr30m, Temperature reading a little low and RH a little high compared to the other sensors 22-oct-1998, ~9:15hr 30m, Temperature reading a 1C lower compared to 20 & 42m. Humidity goes up to 107% 04-nov-1998, ~9:05hr Sensors at 1 &" "amp; 10m sometimes giving bad data (compared to other sensors). 10m RH reading a little high (max = 102%)" "" "Lutz 42m" "ETGage" "Cleaned" "" "" 14/08/2013 14/08/2013 "Clean ETGage and replace GorTex covering" "" "" "" "Lutz 42m" "Rain Gauge" "Installed" "" "" 14/09/1989 14/09/1989 "Install rain gauge on tower" "" "" "" "Lutz 42m" "RH sensor" "Replaced" "" "" 14/10/1992 14/10/1992 "Replace Relative Humidity sensor" "Stilling pond full of sediment. Recorder reads 126mm because the sediment does not let the water drain." "" "" "Lutz 42m" "ETGage" "Observation" "" "" 14/10/1996 14/10/1996 "Bad data" "" "" "" "Lutz 42m" "Tipping Bucket" "Observation" "" "" 14/12/1993 14/12/1993 "Bad data" "Beginning around the 14th the data from the tower tipping bucket are bad" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 14/12/1995 29/12/1995 "Bad data" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 15/03/1999 15/03/1999 "ETGage broken" "Data estimated from other gauges" "" "" "Lutz 42m" "PAR sensor" "Calibrated" "" "" 15/03/2000 15/03/2000 "Calibrate PAR sensors" "" "" "" "Lutz 42m" "Anemometer" "Observation" "" "" 15/06/1988 15/06/1988 "MRI Anemometer not recording wind speed" "" "" "" "Lutz 42m" "Psychrometer" "Replaced" "" "" 15/07/2005 15/07/2005 "Replace Psychrometer after old one broke" "" "" "" "Lutz 42m" "ETGage" "Moved" "" "" 15/10/2001 15/10/2001 "Relocate ETGage to supporting arm off the side of the tower" "Replace ISCO with bubbler/sampler." "" "" "Lutz 42m" "Psychrometer" "Replaced" "" "" 15/12/2004 15/12/2004 "Replace Psychrometer after old one broke" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 16/01/1996 16/01/1996 "Questionable data" "Heavy rain caused water to enter the ETGage" "" "" "Lutz 42m" "Rain Gauge" "Observation" "" "" 16/01/1996 16/01/1996 "Rain gauge overflowed due to very heavy rain" "" "" "" "Lutz 42m" "ETGage" "Replaced" "" "" 16/03/1999 16/03/1999 "ETGage replaced" "" "" "" "Lutz 42m" "T&H sensor" "Replace shield" "" "" 16/03/2010 16/03/2010 "Shield Replacement" "BCI_LUTZ2 42meter Shield. Removed a dirty 12 gill RM Young Shield Installed a clean- 6 gill RM Young Shield" "" "" "Lutz 42m" "Enclosure" "Replace shield" "" "" 16/05/2011 16/05/2011 "Replace Termp/Hum radiation shield with new model" "Temp/Humdity radiation shield changed for new model @ ~10:00hr" "" "" "Lutz 42m" "PAR sensor" "Calibrated" "" "" 16/06/1992 16/06/1992 "Calibrate PAR sensor" "Sensor broken between July 10 @ 12:10hr and Oct. 14" "" "" "Lutz 42m" "Totalizing Anemometer" "Repaired" "" "" 16/10/2006 17/10/2006 "Repair Totalizing anemometer" "Anemometer taken down on the 16th and reinstalled on the 17th following repairs" "" "" "Lutz 42m" "Anemometer" "Calibrated" "" "" 16/11/1998 16/11/1998 "Calibrate Anemometer" "19-nov-1998Relationship between temperature readings keeps changing. Not sure which sensor is having problems, but seems to be the one at 20m. 01-dec-1998 Sensor continues to give problems 17-dec-1998 1m Temperature sensor continues to give problems. R" "eads 26.2C while all the others [10, 20 & 30m] read ~25C. The temperature at 42m is 26.6C [this sensor normally reads higher than the rest due to its exporsure to warmer air]" "" "Lutz 42m" "PAR sensor" "Installed" "" "" 16/11/1998 16/11/1998 "Installed second PAR sensor connected to LiCor datalogger" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 16/11/2001 16/11/2001 "Bad data" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 42m" "Anemometer" "Observation" "" "" 17/02/1989 17/02/1989 "Problem with Anemometer" "" "" "" "Lutz 42m" "ETGage" "Replaced" "" "" 17/03/1994 17/03/1994 "Replace anemometer" "" "" "" "Lutz 42m" "T&H sensor" "Calibrated" "" "" 17/04/2009 17/04/2009 "Calibrate Temp&hum sensor against sling psychrometer" "Hour Dry Bulb Wet Bulb10:07 30.0 24.5" "" "" "Lutz 42m" "Tipping Bucket" "Observation" "" "" 17/07/1995 17/07/1995 "Tipping bucket tested to see if it is working" "Data logger replace because temperatures considered to be slightly lower that they should be. Not know which heights are involved." "" "" "Lutz 42m" "Totalizing Anemometer" "Discontinued" "" "" 17/07/2007 17/07/2007 "Take down Totalizing anemometer" "" "" "" "Lutz 42m" "Anemometer" "Calibrated" "" "" 17/11/1997 17/11/1997 "Calibrate Anemometer" "" "" "" "Lutz 42m" "PAR sensor" "Observation" "" "" 17/12/1997 17/12/1997 "Questionable data" "PAR sensor giving unusual data, but later stabilized" "" "" "Lutz 42m" "T&H sensor" "Modified" "" "" 17/12/2012 17/12/2012 "Replace radiation shield" "" "" "" "Lutz 42m" "Rain Gauge" "Discontinued" "" "" 18/06/1990 18/06/1990 "Totalizing rain gauge on tower removed" "Sensor damaged. Replaced" "" "" "Lutz 42m" "Anemometer" "Observation" "" "" 18/08/1988 18/08/1988 "MRI Anemometer timing off" "" "" "" "Lutz 42m" "Anemometer" "Reprogrammed" "" "" 18/08/1988 18/08/1988 "MRI Anemometer hour corrected" "Anemometer disconected for one hour to correct the time" "" "" "Lutz 42m" "Anemometer" "Replaced" "" "" 18/08/1989 18/08/1989 "Replace Vaisala Anemometer" "" "" "" "Lutz 42m" "Anemometer" "Reprogrammed" "" "" 18/08/1989 18/08/1989 "Adjust Anemometer windspeed threshold" "Adjusted the maximum windspeed threshold (up or down?). This would affect the resolution of the data" "" "" "Lutz 42m" "Anemometer" "Reprogrammed" "" "" 18/08/1989 18/08/1989 "Reprogram Anemometerto to give average wind speed" "Adjusted the maximum windspeed threshold (up or down?). This would affect the resolution of the data" "" "" "Lutz 42m" "Anemometer" "Discontinued" "" "" 18/08/1989 18/08/1989 "Disconnected Vaisala Anemometer wind speed sensor" "Sensor replaced at 13:15hr" "" "" "Lutz 42m" "Psychrometer" "Replaced" "" "" 18/08/1994 18/08/1994 "Replace Pyschrometer" "New pyschrometer. Units now in Celcius" "" "" "Lutz 42m" "Pyranometer" "Calibrated" "" "" 18/09/1990 21/09/1990 "Calibrate Pyranometer" "Calibration sensor left beside deployed sensor between Sept 18 and 21" "" "" "Lutz 42m" "PAR sensor" "Calibrated" "" "" 18/09/1990 21/09/1990 "Calibrate PAR sensor" "Calibration sensor left beside deployed sensor between Sept 18 and 21" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 18/09/2006 18/09/2006 "Bad data" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 42m" "Pyranometer" "Modified" "" "" 18/10/1985 18/10/1985 "Add bands to Pyranometer" "" "" "" "Lutz 42m" "Tipping Bucket" "Observation" "" "" 18/11/1992 20/11/1992 "Tipping bucket not working" "" "" "" "Lutz 42m" "ISCO" "Repaired" "" "" 18/12/1996 18/12/1996 "Adjust ISCO calibration to match true values" "ISCO was reading 30mm when it should have been72mm" "" "" "Lutz 42m" "T&H sensor" "Replaced" "" "" 18/12/2001 18/12/2001 "Replace Temp/Hum sensor" "" "" "" "Lutz 42m" "T&H sensor" "Replace shield" "" "" 19/04/2011 19/04/2011 "Change T&RH shields" "April 19, 2011 Changed the T&RH shields by clean shields at 20m. Datalogger shutdown at 11:40 Datalogger powered up at 11:50 The datalogger program did not re-start automatically after the datalogger was powered up. The program had to be re-started" "on April 21 at 20:30. Inspected the equipment all equipment at BCI" "" "Lutz 42m" "Datalogger" "Observation" "" "" 19/04/2011 19/04/2011 "Datalogger did not correctly restart" "April 19, 2011 Datalogger shutdown at 11:40 Datalogger powered up at 11:50 The datalogger program did not re-start automatically after the datalogger was powered up. The program had to be re-started on April 21 at 20:30." "" "" "Lutz 42m" "Air Temp Sensor" "Moved" "" "" 19/05/1993 19/05/1993 "Move sensor to inside of shelter" "" "" "" "Lutz 42m" "ETGage" "Cleaned" "" "" 19/06/2014 19/06/2014 "Clean ETGage and replace GorTex covering" "" "" "" "Lutz 42m" "T&H sensor" "Installed" "" "" 19/07/1993 19/07/1993 "Install Rotronic T&H sensor" "Rotronic T&H sensor was disconnected because the data were bad" "" "" "Lutz 42m" "PAR sensor" "Calibrated" "" "" 19/08/1992 19/08/1992 "Calibrate PAR sensor" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 19/08/1998 19/08/1998 "Bad data" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 19/11/2001 20/11/2001 "Bad data" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 42m" "Pyranometer" "Replaced" "" "" 20/01/2000 20/01/2000 "Replace Pyranometer" "Replace datalogger with datalogger removed on Jan 20 from the Clearing. The datalogger had problems reading temperature data." "" "" "Lutz 42m" "Pyranometer" "Replaced" "" "" 20/01/2000 20/01/2000 "Replace PAR sensor" "" "" "" "Lutz 42m" "Thermometer" "Observation" "" "" 20/02/2014 20/02/2014 "Scale shifts - readings a bit unreliable" "" "" "" "Lutz 42m" "Psychrometer" "Replaced" "" "" 20/04/2015 20/04/2015 "Replace Psychrometer after old one broke" "" "" "" "Lutz 42m" "Anemometer" "Cleaned" "" "" 20/06/1989 20/06/1989 "Clean Vaisala Anemometer" "" "" "" "Lutz 42m" "Ultraviolet sensor" "Installed" "" "" 20/07/1988 20/07/1988 "Install Sunburning UV sensor" "" "" "" "Lutz 42m" "PAR sensor" "Calibrated" "" "" 20/08/1993 20/08/1993 "Calibrate PAR sensor" "Replace electronic ETGage (Atmometer) with manual gauge" "" "" "Lutz 42m" "ETGage" "Deactivated" "" "" 20/08/1998 21/08/1998 "Remove ETGage" "Humidity is higher than either 20m or 42m and occasionally reads above 100%. RH returns to normal on very sunny days" "" "" "Lutz 42m" "Tipping Bucket" "Repaired" "" "" 20/11/1992 20/11/1992 "Repair Tipping bucket" "Sensor changed at 12:10hr" "" "" "Lutz 42m" "Datalogger" "Observation" "" "" 21/04/2011 21/04/2011 "Restart Datalogger" "July 11, 2011 Logger shutdown at 10:07 - Installed new CS 215 chip at 20m and 42m - Noticed that the new 42m chip was reading high - replaced this chip at 11:47 Logger powered up at 10:28 Logger shutdown at 11:47 - Given that the new chip installed at 4" "2m was reading high, the old chip from 20m was installed at 42m - A new chip will be sent to Raul for installation at 42m Logger powered up at 12:10" "" "Lutz 42m" "Datalogger" "Observation" "" "" 21/05/1999 26/05/1999 "Unable to establish contact with datalogger" "Previous 24 days of data were lost" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 21/06/1999 22/06/1999 "Gauge broken during the weekend" "Data estimated from other gauges" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 21/06/2010 21/06/2010 "Bad data" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 21/07/2010 21/07/2010 "Bad data" "" "" "" "Lutz 42m" "ETGage" "Installed" "" "" 21/08/1998 21/08/1998 "Install ETGage" "" "" "" "Lutz 42m" "ISCO" "Repaired" "" "" 21/10/1996 21/10/1996 "Adjust ISCO calibration to match true values" "" "" "" "Lutz 42m" "ISCO" "Repaired" "" "" 22/03/1996 22/03/1996 "Adjust ISCO calibration to match true values" "ISCO registering too high" "" "" "Lutz 42m" "T&H sensor" "Modified" "" "" 22/03/2012 22/03/2012 "Replace radiation shield @ 10:15hr" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 22/05/2002 22/05/2002 "ETGage broken" "Stilling pond was over filled following cleaning. Stablized at correct value ~15:00hr" "" "" "Lutz 42m" "Anemometer" "Reprogrammed" "" "" 22/06/1988 22/06/1988 "Adjust hour on datalogger" "" "" "" "Lutz 42m" "ISCO" "Repaired" "" "" 22/06/1995 22/06/1995 "Adjust ISCO calibration to match true values" "ISCO registering 169mm while manual reading is 157mm" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 22/06/1995 23/06/1995 "Bad data" "Probably bad datum after heavy rain (this eventually turned out to be a problem of water getting inside of the device)" "" "" "Lutz 42m" "T&H sensor" "Observation" "" "" 22/06/1998 22/06/1998 "Bad data" "" "" "" "Lutz 42m" "Datalogger" "Observation" "" "" 22/07/1999 22/07/1999 "Datalogger Lutz2 not working" "" "" "" "Lutz 42m" "Datalogger" "Observation" "" "" 22/07/1999 22/07/1999 "Datalogger not working" "" "" "" "Lutz 42m" "T&H sensor" "Replaced" "E4058" "A4910019" 22/07/2009 22/07/2009 "Replace T&H sensor with new model" "July 22, 2009 Installed CS215 Temp&RH sensor at 42m, S/N E4058 Removed HMP45C T&RH sensor at 42m, S/N X0410079 - Vaisala S/N A4910019" "" "" "Lutz 42m" "Datalogger" "Reprogrammed" "" "" 22/07/2009 22/07/2009 "Reprogram Datalogger" "July 22, 2009 Installed CS215 Temp&RH sensor at 20m, S/N E2899 Installed CS215 Temp&RH sensor at 42m, S/N E4058 New program bci_Lutz2_20090715kk.CR1 was uploaded at 2:43 p.m. Removed HMP45C T&RH sensor at 20m, S/N Y3250082 - Vaisala S/N Z38" "10012 Removed HMP45C T&RH sensor at 42m, S/N X0410079 - Vaisala S/N A4910019" "" "Lutz 42m" "Thermometer" "Replaced" "" "" 22/12/2014 22/12/2014 "Replace Max/min thermometer" "Thermometer giving problems with readings. The internal bar enters the mercury column. Replacement thermometer giving same problem" "" "" "Lutz 42m" "Datalogger" "Replaced" "" "" 23/01/1991 23/01/1991 "Replace Datalogger" "" "" "" "Lutz 42m" "Air Temp Sensor" "Replaced" "" "" 23/02/1993 23/02/1993 "Replace LiCor temperature sensor" "Sensor moved inside of the shelter. The same place as the Rotronic T&H sensor" "" "" "Lutz 42m" "Pyranometer" "Repaired" "" "" 23/05/1988 23/05/1988 "Repair Pyranometer cable" "" "" "" "Lutz 42m" "Pyranometer" "Calibrated" "" "" 23/06/1986 23/06/1986 "Calibrate Pyranometer" "" "" "" "Lutz 42m" "Anemometer" "Calibrated" "" "" 23/06/1986 23/06/1986 "Calibrate Anemometer" "" "" "" "Lutz 42m" "Anemometer" "Calibrated" "" "" 23/06/1997 23/06/1997 "Calibrate Anemometer" "Anemometer calibrated and direction adjusted to better match true north (by how much?)" "" "" "Lutz 42m" "Enclosure" "Replaced" "" "" 23/12/1997 23/12/1997 "Replace instrument shelter" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 24/05/1996 24/05/1996 "Bad data" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 42m" "Air Temp Sensor" "Repaired" "" "" 24/06/1986 24/06/1986 "Fix Temperature sensor" "" "" "" "Lutz 42m" "Anemometer" "Observation" "" "" 24/10/1988 24/10/1988 "MRI Anemometer not working" "" "" "" "Lutz 42m" "Anemometer" "Deactivated" "" "" 24/10/1988 24/10/1988 "Take MRI Anemometer offline" "" "" "" "Lutz 42m" "Anemometer" "Replaced" "" "" 25/03/1992 25/03/1992 "Replace Anemometer" "Anemometer 'A' replaced with Anemometer 'B' between 9:15 & 10:40hr" "" "" "Lutz 42m" "Anemometer" "Reprogrammed" "" "" 25/03/1997 25/03/1997 "Reprogram datalogger to correct anemometer error" "" "" "" "Lutz 42m" "ETGage" "Cleaned" "" "" 25/04/2001 25/04/2001 "Replace GorTex covering on ETGage" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 25/05/1999 26/05/1999 "Bad data" "" "" "" "Lutz 42m" "Thermometer" "Observation" "" "" 25/08/1992 25/08/1992 "Max/Min thermometer broken" "" "" "" "Lutz 42m" "Thermometer" "Replaced" "" "" 25/08/1992 25/08/1992 "Replace Max/Min thermometer" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 25/09/2006 25/09/2006 "ETGage leaking water" "Looks like someone adjusted the pressure" "" "" "Lutz 42m" "ETGage" "Replaced" "" "" 25/09/2006 25/09/2006 "Replace ETGage" "" "" "" "Lutz 42m" "Ultraviolet sensor" "Repaired" "" "" 25/10/1985 25/10/1985 "Install new cable for Ultraviolet sensor" "" "" "" "Lutz 42m" "ISCO" "Observation" "" "" 25/10/1994 25/10/1994 "Bad data" "ISCO working but not storing data" "" "" "Lutz 42m" "ETGage" "Modified" "" "" 25/11/2009 25/11/2009 "Replace GorTex covering on ETGage" "" "" "" "Lutz 42m" "T&H sensor" "Observation" "" "" 26/02/1992 28/02/1992 "Battery on datalogger drained" "" "" "" "Lutz 42m" "Anemometer" "Observation" "" "" 26/02/1992 28/02/1992 "Battery on datalogger drained" "Battery went bad at ~16:00hr. Data bad until Feb 28 @ 9:15hr" "" "" "Lutz 42m" "Datalogger" "Replaced" "" "" 26/05/1999 26/05/1999 "Replace datalogger" "" "" "" "Lutz 42m" "Anemometer" "Calibrated" "" "" 26/05/1999 26/05/1999 "Calibrate Anemometer" "Data estimated from other gauges" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 26/05/1999 27/05/1999 "Bad data" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 26/05/2000 26/05/2000 "Water lost from ETGage. Reservoir refilled" "" "" "" "Lutz 42m" "Pyranometer" "Replaced" "" "" 26/06/1999 26/06/1999 "Replace Pyranometer" "" "" "" "Lutz 42m" "T&H sensor" "Observation" "" "" 26/07/2001 26/07/2001 "Humidity may be 4-5% too high" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 26/08/1996 26/08/1996 "Bad data" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 42m" "Anemometer" "Replaced" "" "" 26/09/1990 26/09/1990 "Replace Young Anemometer" "Young Anemometer replaced at ~11:20hr" "" "" "Lutz 42m" "Anemometer" "Observation" "" "" 26/09/1990 26/09/1990 "Anemometer found not connected to battery" "Clean sediment from stilling pond. Work finished ~ 10:00hr on the 14th" "" "" "Lutz 42m" "ISCO" "Repaired" "" "" 26/12/1996 26/12/1996 "Adjust ISCO calibration to match true values" "ISCO was reading 20mm too high" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 26/12/1997 26/12/1997 "ETGage not working" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 27/01/1997 28/01/1997 "Giving problems" "" "" "" "Lutz 42m" "Air Temp Sensor" "Moved" "" "" 27/03/1991 27/03/1991 "Move Air temperature sensor" "Sensor moved so that it no longer touched the side of the instrument shelter" "" "" "Lutz 42m" "Anemometer" "Repaired" "" "" 27/04/1988 27/04/1988 "Paper for Anemometer adjusted to fix the time" "" "" "" "Lutz 42m" "ETGage" "Modified" "" "" 27/09/2011 27/09/2011 "Replace ETGage support" "" "" "" "Lutz 42m" "Pyranometer" "Repaired" "" "" 28/01/1991 28/01/1991 "Fix SR datalogger" "Unspecified problem with SR datalogger resolved" "" "" "Lutz 42m" "PAR sensor" "Repaired" "" "" 28/01/1991 28/01/1991 "Fix SR datalogger" "Unspecified problem with SR datalogger resolved" "" "" "Lutz 42m" "ETGage" "Replaced" "" "" 28/01/1997 28/01/1997 "Replace ETGage" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 42m" "Anemometer" "Calibrated" "" "" 28/01/1999 28/01/1999 "Calibrate Anemometer" "" "" "" "Lutz 42m" "ETGage" "Replaced" "" "" 28/02/1994 28/02/1994 "Replace anemometer" "" "" "" "Lutz 42m" "Ultraviolet sensor" "Installed" "" "" 28/09/1988 28/09/1988 "Sunburning UV sensor not working" "" "" "" "Lutz 42m" "Ultraviolet sensor" "Deactivated" "" "" 28/09/1988 28/09/1988 "Sunburning UV sensor disconnected" "Anemometer not registering all data due to problems with the battery" "" "" "Lutz 42m" "Pyranometer" "Replaced" "" "" 28/10/1991 28/10/1991 "Replace Pyranometer" "Unspecified problem with SR datalogger resolved" "" "" "Lutz 42m" "PAR sensor" "Replaced" "" "" 28/10/1991 28/10/1991 "Replace PAR sensor" "Unspecified problem with SR datalogger resolved" "" "" "Lutz 42m" "Anemometer" "Observation" "" "" 29/04/1988 30/04/1988 "Data probably bad for the 29th and 30th" "" "" "" "Lutz 42m" "T&H sensor" "Replaced" "" "" 29/04/1993 29/04/1993 "Replace Rotronic T&H sensor" "Sensor moved inside of the shelter. The same place as the Rotronic T&H sensor" "" "" "Lutz 42m" "Air Temp Sensor" "Observation" "" "" 29/05/1987 29/05/1987 "Datalogger showing problems" "Replace max/min thermometer. First reading with new thermometer was on the next day" "" "" "Lutz 42m" "T&H sensor" "Deactivated" "" "" 29/06/1993 29/06/1993 "Disconnect Rotronic T&H sensor" "Rotronic T&H sensor was disconnected because the data were bad" "" "" "Lutz 42m" "Datalogger" "" "" "" 29/07/2014 29/07/2014 "Replaced datalogger Lutz2" "July 29th, 2014 The datalogger (CR1000 SN:16395) stopped running on July 22, 2014 @ 11:00 am There was a battery problem detected a few days earlier Removed logger CR1000 SN:16395 Installed CR1000 SN:31713 w/program bci_lutz2_20120710kk.CR1 Logger power-" "up at 10:40 am" "" "Lutz 42m" "Pyranometer" "Modified" "" "" 29/10/1985 29/10/1985 "Remove bands from Pyranometer" "Sensor repaired. Bands had been moved." "" "" "Lutz 42m" "Anemometer" "Replaced" "" "" 29/10/1993 29/10/1993 "Replace anemometer" "" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 29/10/2001 29/10/2001 "Bad data" "" "" "" "Lutz 42m" "T&H sensor" "Installed" "" "" 29/11/1991 29/11/1991 "Install Temp/Hum sensor" "This may be the first installation of a Rotronics T&H sensor on the tower. The sensor was most likely installed at 42m Raul says that the original Temperature sensor was left in place for 'some time'" "" "" "Lutz 42m" "ETGage" "Observation" "" "" 30/05/1995 30/05/1995 "Bad data" "Probably bad datum after heavy rain (this eventually turned out to be a problem of water getting inside of the device)" "" "" "Lutz 42m" "Tipping Bucket" "Observation" "" "" 30/06/1994 18/07/1994 "Bad data" "Tower tipping bucket not working between June 30 and July 18" "" "" "Lutz 42m" "Thermometer" "Repaired" "" "" 30/06/2014 30/06/2014 "Mercury split - repaired" "" "" "" "Lutz 42m" "Tipping Bucket" "Repaired" "" "" 30/08/1991 30/08/1991 "Repair Tipping Bucket" "" "" "" "Lutz 48m" "Anemometer" "Calibrated" "" "" 01/06/2009 01/06/2009 "Calibrate Anemometer direction" "Hour Dry Bulb Wet Bulb10:13 30.0 25.0" "" "" "Lutz 48m" "Thermometer" "Installed" "" "" 01/07/2002 01/07/2002 "Install Max/Min thermometers" "" "" "" "Lutz 48m" "Anemometer" "Moved" "" "" 01/11/2001 01/11/2001 "Move Anemometer from 42m to 48m" "Totalizing anemometer from the Clearing was installed beside the existing anemometer at 42m in order to compare them" "" "" "Lutz 48m" "Datalogger" "Replaced" "X19475" "X07046" 02/06/2009 02/06/2009 "Replace datalogger" "On June 2, 2009 the station went into maintenace between 11:38 and 14:30. -Installed new calibrated logger SN X19475 along with a new logger program: bci_Lutz120090602kk - the PakBus address of this logger is 31." "" "" "Lutz 48m" "T&H sensor" "Repaired" "B3130015" "B1540025" 02/06/2009 02/06/2009 "Replace sensor head on T&H sensor" "On June 2, 2009 the station went into maintenace between 11:38 and 14:30. -Replaced the sensor head on the HMP45C(7WCS) AirTC and RH sensor, located at 48m." "" "" "Lutz 48m" "T&H sensor" "Replaced" "B3130015" "" 02/06/2009 02/06/2009 "Replace Temp/Hum sensor" "" "" "" "Lutz 48m" "Datalogger" "Reprogrammed" "" "" 02/07/2007 02/07/2007 "LiCor datalogger reporgrammed to log every 15-minutes" "" "" "" "Lutz 48m" "PAR sensor" "Observation" "" "" 03/01/2002 03/01/2002 "Sensor cable broken" "" "" "" "Lutz 48m" "PAR sensor" "Repaired" "" "" 03/01/2002 03/01/2002 "Repair Sensor cable" "" "" "" "Lutz 48m" "Pyranometer" "Battery Replaced" "" "" 03/01/2002 03/01/2002 "Replace battery of LiCor logger" "" "" "" "Lutz 48m" "ETGage" "Replaced" "" "" 03/01/2008 03/01/2008 "Replace ETGage" "Hour Dry Bulb Wet Bulb10:35 29.5 25.0" "" "" "Lutz 48m" "Thermometer" "Observation" "" "" 03/01/2011 03/02/2011 "Max. temperature unexpectedly low" "" "" "" "Lutz 48m" "Anemometer" "Replaced" "59509" "25133" 03/06/2009 03/06/2009 "Replace Anemometer" "On June 2, 2009 the station went into maintenace between 11:38 and 14:30. -Replaced anemometer. Old anemometer YOUNG SN25133. New anemometer Y05103 SN59509. The program for this new anemometer has no offset values for WindVelocity or WindDir. The north m" "arker on the pole of the anemometer was moved approx. 2 degrees to the west." "" "Lutz 48m" "PAR sensor" "Discontinued" "" "" 03/06/2009 03/06/2009 "PAR sensor discontinued due to difficulty getting good data" "On June 2, 2009 the station went into maintenace between 11:38 and 14:30. -Quantum sensor readings were discontinued on this date." "" "" "Lutz 48m" "Battery" "Replaced" "" "" 03/06/2009 03/06/2009 "Replace Battery Regulator" "A new battery regulator was installed on Lutz2 at 11:30 a.m.June 3rd, 2009" "" "" "Lutz 48m" "PAR sensor" "Observation" "" "" 03/10/2006 03/10/2006 "PAR #1 is reading too low" "" "" "" "Lutz 48m" "Pyranometer" "Observation" "" "" 04/10/2001 04/10/2001 "Quartz sensor scratched" "" "" "" "Lutz 48m" "PAR sensor" "Observation" "" "" 04/10/2001 04/10/2001 "Quartz sensor scratched" "" "" "" "Lutz 48m" "Anemometer" "Replaced" "" "" 04/12/2002 04/12/2002 "Replace Anemometer" "" "" "" "Lutz 48m" "Anemometer" "Calibrated" "" "" 04/12/2002 04/12/2002 "Calibrate Anemometer" "" "" "" "Lutz 48m" "Totalizing Anemometer" "Observation" "" "" 05/01/2007 19/01/2007 "Totalizing anemometer broken" "Anemometer taken down on Jan 5 and replaced on the 19th" "" "" "Lutz 48m" "Psychrometer" "Replaced" "" "" 05/03/2004 05/03/2004 "Replace Psychrometer after old one broke" "" "" "" "Lutz 48m" "T&H sensor" "Replaced" "" "" 05/04/2006 05/04/2006 "Replace Temp/Hum sensor" "" "" "" "Lutz 48m" "T&H sensor" "Replaced" "" "" 05/04/2006 05/04/2006 "Replace Temp/Hum sensor" "Was every 5-minutes" "" "" "Lutz 48m" "Thermometer" "Observation" "" "" 05/04/2010 05/04/2010 "Max. temperature unexpectedly low" "" "" "" "Lutz 48m" "Thermometer" "Observation" "" "" 06/02/2012 06/02/2012 "Max. temperature unexpectedly low" "" "" "" "Lutz 48m" "T&H sensor" "Replaced" "b1540025" "a4910012" 06/11/2007 06/11/2007 "Replace Temp/Hum sensor" "" "" "" "Lutz 48m" "Anemometer" "Replaced" "101114" "73886" 07/02/2013 07/02/2013 "Replace Anemometer" "Feb. 7th, 2013 Logger shutdown at 9:27 -Removed anemometer RM Young 05103 SN:73886 -Installed calibrated anemomter RM Young 05103 SN:101114 Logger power-up at 11:11" "" "" "Lutz 48m" "Anemometer" "Observation" "" "" 07/05/2002 07/05/2002 "Problems (?) with Anemometer" "Exact data of replacement uncertain - probably about two weeks before this date" "" "" "Lutz 48m" "Pyranometer" "Discontinued" "" "" 09/05/2003 09/05/2003 "Pyranometer connected to LiCor discontinued" "" "" "" "Lutz 48m" "Datalogger" "Reprogrammed" "" "" 09/07/2012 09/07/2012 "Convert to MySQL" "July 2nd, 2012 The BCI Lutz1 station has been fully converted to MySQL. Created and uploaded a new program bci_lutz120120702.CR1 The program was uploaded at 15:35" "" "" "Lutz 48m" "Datalogger" "Reprogrammed" "" "" 09/07/2012 09/07/2012 "Adjust datalogger program" "July 7th, 2012 Adjusted the Lutz1 datalogger program. The imput location names for Air Temp and RH contain the height of the sensor, i.e. 48m. The program loaded was bci_Lutz120120709kk.CR1 w/ impunt locations..." "TIMESTAMP" ", "RECORD", "PBID", 1"BattV_A""" "Lutz 48m" "ETGage" "Observation" "" "" 09/08/2005 09/08/2005 "Bad data" "" "" "" "Lutz 48m" "Psychrometer" "Replaced" "" "" 09/09/2013 09/09/2013 "Replace Psychrometer after old one broke" "" "" "" "Lutz 48m" "ETGage" "Observation" "" "" 09/11/2004 11/11/2004 "Bad data" "" "" "" "Lutz 48m" "Pyranometer" "Installed" "" "" 10/01/2002 10/01/2002 "Install second Pyranometer" "" "" "" "Lutz 48m" "ETGage" "Cleaned" "" "" 10/04/2012 10/04/2012 "Clean ETGage and replace GorTex covering" "" "" "" "Lutz 48m" "Pyranometer" "Replaced" "73920" "67786" 10/12/2012 10/12/2012 "Replace Pyranometer east" "Monday Dec. 10, 2012 Station shutdown at 11:19 am -Removed pyranometers: East PY67786 -Installed pyranomters: East PY73920 Station powered-up at 12:15 pm" "" "" "Lutz 48m" "Pyranometer" "Replaced" "73921" "67788" 10/12/2012 10/12/2012 "Replace Pyranometer west" "Monday Dec. 10, 2012 Station shutdown at 11:19 am -Removed pyranometers: West PY67788 -Installed pyranomters: West PY73921 Station powered-up at 12:15 pm" "" "" "Lutz 48m" "PAR sensor" "Installed" "33002" "" 11/06/2007 11/06/2007 "Install new PAR sensor" "" "" "" "Lutz 48m" "Pyranometer" "Replaced" "63943" "8176" 11/06/2009 11/06/2009 "Replace Pyranometer with new model" "A new Pyranomter will be sento Raul on June 9, 2009. The new Pyranomter is LI200S - PY63943.This Pyranometer will replace the CS300 Apogee pyranometer currently installed at LUTZ1. The new program to load on LUTZ1 is bci_Lutz120090609.dld ++++++++++++++" "++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ June 11, 2009 -Station power-down time: 10:15 am. -A new pyranomter LI200S - PY63943, was installed -Apog" "ee pyranometer CS300 SN:8176 removed. -Station power up time: 10:43 am -The new program ( bci_Lutz120090609.dld) was loaded @ 11:05 am." "Lutz 48m" "ETGage" "Observation" "" "" 12/05/2011 12/05/2011 "Bad data" "" "" "" "Lutz 48m" "Anemometer" "Repaired" "" "" 12/06/2006 12/06/2006 "Repair Anemometer" "Replaced bearings" "" "" "Lutz 48m" "ETGage" "Replaced" "" "" 13/01/2003 13/01/2003 "Replace ETGage" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 48m" "Anemometer" "Repaired" "" "" 13/01/2006 13/01/2006 "Repair Anemometer" "Anemometer repaired. No indication given of problem" "" "" "Lutz 48m" "T&H sensor" "Modified" "" "" 13/12/2012 13/12/2012 "Replace radiation shield" "" "" "" "Lutz 48m" "Pyranometer" "Moved" "67786" "" 14/02/2011 14/02/2011 "Restored Pyranometer to original position" "Feb. 14, 2011 During the installation of the CTFS pyranometer the Lutz pyranomters got switched: PY67786 was placed to the west On Feb 14 the pyranomters were restablised to the original deployment positions: PY67786 now east" "" "" "Lutz 48m" "Pyranometer" "Moved" "67788" "" 14/02/2011 14/02/2011 "Restored Pyranometer to original position" "Feb. 14, 2011 During the installation of the CTFS pyranometer the Lutz pyranomters got switched: PY67788 was placed to the east. On Feb 14 the pyranomters were restablised to the original deployment positions: PY67788 now west" "" "" "Lutz 48m" "ETGage" "Observation" "" "" 14/05/2007 15/05/2007 "Broken" "Exterior glass tube broken" "" "" "Lutz 48m" "Pyranometer" "Replaced" "SP151576" "PY79965" 14/06/2016 14/06/2016 "Replaced East Pyranometer" "" "" "" "Lutz 48m" "Pyranometer" "Replaced" "PY86635" "PY79566" 14/06/2016 14/06/2016 "Replaced West Pyranometer" "" "" "" "Lutz 48m" "Datalogger" "Reprogrammed" "35285" "35285" 14/06/2016 14/06/2016 " Reprog logger w/SPLite2 - wrong multiplier" "" "" "" "Lutz 48m" "Datalogger" "Reprogrammed" "35285" "35285" 14/06/2016 14/06/2016 "Reprog logger - corrected SPLite2 multiplier" "" "" "" "Lutz 48m" "ETGage" "Cleaned" "" "" 14/08/2013 14/08/2013 "Clean ETGage and replace GorTex covering" "" "" "" "Lutz 48m" "Datalogger" "Replaced" "35285" "07046" 14/10/2010 14/10/2010 "Replace datalogger with new model" "October 14th, 2010. -Station powered down at 10:05 a.m. -Removed the datalogger CR10XPB S/N:07046 -Installed the datalogger CR1000 S/N:35285 with program bci_lutz120101014.CR1" "" "" "Lutz 48m" "T&H sensor" "Replaced" "E4953" "B3130015" 14/10/2010 14/10/2010 "Replace T&H sensor with new model" "October 14th, 2010. -Station powered down at 10:05 a.m. -Removed the T&RH sensor Vaisala HMP45 ASP, S/N:B3130015 -Installed T&RH C215 S/N:E4953" "" "" "Lutz 48m" "ETGage" "Replaced" "" "" 15/05/2007 15/05/2007 "Repair ETGage" "Anemometer was damaged on Aug 13 and was not repairable" "" "" "Lutz 48m" "Pyranometer" "Misc" "SP151576" "SP151576" 15/06/2016 15/06/2016 "Re-leveled East Pyranometer" "" "" "" "Lutz 48m" "Pyranometer" "Misc" "PY86635" "PY86635" 15/06/2016 15/06/2016 "Re-leveled West Pyranometer" "" "" "" "Lutz 48m" "Psychrometer" "Replaced" "" "" 15/07/2005 15/07/2005 "Replace Psychrometer after old one broke" "" "" "" "Lutz 48m" "T&H sensor" "Observation" "" "" 15/09/2003 15/09/2003 "Temperature data bad" "" "" "" "Lutz 48m" "Totalizing Anemometer" "Installed" "" "" 15/10/2001 15/10/2001 "Install Totalizing anemometer at 48m" "Totalizing anemometers were run at 48m & 42m until July 2007 in order to quanitfy the difference between the two levels" "" "" "Lutz 48m" "Anemometer" "Observation" "" "" 15/10/2001 15/10/2001 "Cable broken" "" "" "" "Lutz 48m" "Anemometer" "Replaced" "" "" 15/10/2001 15/10/2001 "Replace Anemometer" "" "" "" "Lutz 48m" "Psychrometer" "Replaced" "" "" 15/12/2004 15/12/2004 "Replace Psychrometer after old one broke" "" "" "" "Lutz 48m" "Thermometer" "Calibrated" "" "" 16/01/2002 07/03/2002 "Install second Max/Min thermometers for calibration" "" "" "" "Lutz 48m" "Pyranometer" "Replaced" "8176" "46168" 16/09/2008 16/09/2008 "Replace Pyranometer with new model" "Sptember 16, 2009 Installed SR sensor Apogee SN8176 Removed LI-COR LI200X PY46168" "" "" "Lutz 48m" "T&H sensor" "Replace shield" "" "" 17/03/2010 17/03/2010 "Shield Replacement" "March 17, 2010 BCI_LUTZ1 48meter Shield. The shield was replaced by a clean and identical shield - 12 gill RM Young" "" "" "Lutz 48m" "T&H sensor" "Calibrated" "" "" 17/04/2009 17/04/2009 "Calibrate Temp&hum sensor against sling psychrometer" "Hour Dry Bulb Wet Bulb10:13 30.0 25.0" "" "" "Lutz 48m" "Anemometer" "Calibrated" "" "" 17/04/2009 17/04/2009 "Calibrate Anemometer direction" "Hour Dry Bulb Wet Bulb10:13 30.0 25.0" "" "" "Lutz 48m" "T&H sensor" "Replaced" "E7218" "E4953" 17/10/2012 17/10/2012 "Replace T&H sensor" "October 17, 2012 Replaced T&RH sensor at 48m Shutdown datalogger at 9:56 -Removed CS215 T&RH SNE4953 -Installed CS215 T&RH SNE7218 Datalogger powered-up at 10:13" "" "" "Lutz 48m" "Thermometer" "Observation" "" "" 18/02/2009 19/02/2009 "Strong winds may have affected max/min temps" "Strong winds caused the tower to strongly sway back and forth. This may have moved the small bar inside the max/min thermometer" "" "" "Lutz 48m" "ETGage" "Observation" "" "" 18/07/2007 18/07/2007 "Bad data" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 48m" "Anemometer" "Observation" "" "" 19/01/2006 20/01/2006 "Anemometer stopped working" "Stopped working between 13:00 and 15:00hr on the 19th" "" "" "Lutz 48m" "Totalizing Anemometer" "Repaired" "" "" 19/01/2007 19/01/2007 "Repair Totalizing anemometer" "" "" "" "Lutz 48m" "Datalogger" "Replaced" "X07046" "X19475" 19/03/2010 19/03/2010 "Replace datalogger" "Replaced the Dataogger. Removed -Removed CR10XPB S/N X19475, Calibration due date 18 Mar. 2011 -Datalogger had about 6 watchdog errors. -Station Shutdown at 10:00 a.m. Installed -Installed CR10XPB S/N X07046, Calibration due date 25, Feb. 2012 -Program:" " bci_lutz120090602kk.dld Station powered up at 11:03 a.m." "" "Lutz 48m" "Thermometer" "Observation" "" "" 19/06/2012 22/06/2012 "Max/Min thermometer damaged" "" "" "" "Lutz 48m" "ETGage" "Cleaned" "" "" 19/06/2014 19/06/2014 "Clean ETGage and replace GorTex covering" "" "" "" "Lutz 48m" "Pyranometer" "Installed" "67788" "" 19/11/2010 19/11/2010 "Install Pyranometer. Adds back-up sensor to this location" "November 19, 2010From 12:16 to 12:57 INSTALLED: -New pyranomter PY67788 - West pyranomter and going to table BCI_LUTZ1_SRW -New program bci_Lutz120101119kk.CR1" "" "" "Lutz 48m" "Pyranometer" "Replaced" "67786" "63943" 19/11/2010 19/11/2010 "Replace Pyranometer" "November 19, 2010From 12:16 to 12:57 INSTALLED: -New pyranometer PY67786 - East pyranometer and going to table BCI_LUTZ1_SR -New program bci_Lutz120101119kk.CR1 REMOVED: -Pyranometer PY63943" "" "" "Lutz 48m" "Anemometer" "Replaced" "73886" "101114" 19/11/2014 19/11/2014 "Replace Anemometer" "November 19, 2014 Logger shutdown at 9:05 am -Removed 05103 Anemometer SN:101114 -Installed 05103 anemometer SN:73886 Logger powerup at 9:41 am" "" "" "Lutz 48m" "T&H sensor" "Replaced" "E11111" "E4953" 19/11/2014 19/11/2014 "Replaced T&RH Sensor" "November 19, 2014 Logger shutdown at 9:05 am -Removed T&RH CS215 @48m, SN:E4953 -Installed T&RH CS215 @48m, SN:E11111 Logger powerup at 9:41 am" "" "" "Lutz 48m" "Anemometer" "Repaired" "" "" 20/01/2006 20/01/2006 "Repair Anemometer" "" "" "" "Lutz 48m" "Psychrometer" "Replaced" "" "" 20/04/2015 20/04/2015 "Replace Psychrometer after old one broke" "" "" "" "Lutz 48m" "Thermometer" "Observation" "" "" 20/10/2003 20/10/2003 "Door on enclosure found open" "" "" "" "Lutz 48m" "Anemometer" "Repaired" "" "" 20/12/2004 20/12/2004 "Replace propeller bearings" "" "" "" "Lutz 48m" "ETGage" "Replaced" "" "" 21/02/2003 21/02/2003 "Replace ETGage" "" "" "" "Lutz 48m" "ETGage" "Replaced" "" "" 21/02/2011 21/02/2011 "Replace ETGage" "" "" "" "Lutz 48m" "Enclosure" "Replaced" "" "" 21/05/2010 21/05/2010 "New Stevenson screen" "May 21, 2010 Installed new Stevenson screen at Lutz 48m." "" "" "Lutz 48m" "T&H sensor" "Reprogrammed" "E4953" "" 21/10/2010 21/10/2010 "Fixed T&RH code" "October 21, 2010Fixed the T&RH SDI12Recorder(AirTC, ...) destination instruction to the array deatination TRHData() .. ...... as SDI12Recorder(TRHData(), ...)" "" "" "Lutz 48m" "Anemometer" "Replaced" "" "" 21/11/2002 22/11/2002 "Replace Anemometer" "" "" "" "Lutz 48m" "Anemometer" "Observation" "" "" 21/11/2002 04/12/2002 "New Anemometer not registering wind speed" "" "" "" "Lutz 48m" "Anemometer" "Replaced" "73886" "59509" 22/02/2011 22/02/2011 "Replace anemometer" "Feb. 22, 2011 -Station shutdown at 10:15 -Installed calibrated anemometer RM Young 05103 S/N 73886 -Removed anemometer RM Young 05103 S/N 59509 -Station power-up at 10:36" "" "" "Lutz 48m" "T&H sensor" "Modified" "" "" 22/03/2012 22/03/2012 "Replace radiation shield @ 10:00hr" "" "" "" "Lutz 48m" "Anemometer" "Calibrated" "" "" 22/04/2009 22/04/2009 "Calibrate Anemometer direction" "Hour Dry Bulb Wet Bulb10:13 30.0 25.0" "" "" "Lutz 48m" "Anemometer" "Observation" "" "" 22/06/2006 22/06/2006 "Work on tower may have affected the data on this date" "Anemometer taken down on the 25th and replaced on the 26th" "" "" "Lutz 48m" "Thermometer" "Observation" "" "" 22/06/2006 22/06/2006 "Work on tower may have affected the data on this date" "" "" "" "Lutz 48m" "ETGage" "Observation" "" "" 22/06/2006 22/06/2006 "Work on tower may have affected the data on this date" "" "" "" "Lutz 48m" "Totalizing Anemometer" "Observation" "" "" 22/06/2006 22/06/2006 "Work on tower may have affected the data on this date" "" "" "" "Lutz 48m" "Thermometer" "Observation" "" "" 22/06/2009 08/07/2009 "Max. temperature unexpectedly low" "" "" "" "Lutz 48m" "Thermometer" "Repaired" "" "" 22/06/2012 22/06/2012 "Repair Max/Min thermometer @ 15:00hr" "" "" "" "Lutz 48m" "T&H sensor" "Replaced" "E4953" "E7218" 22/10/2013 22/10/2013 "Replace T&RH sensor" "October 22, 2013 Logger shutdown at 9:38 -Removed Lutz48m CS215 T&RH sensor SN:E7218 -Installed Lutz48m CS215 T&RH sensor SN:E4953 Logger power-up at 10:07" "" "" "Lutz 48m" "Thermometer" "Observation" "" "" 23/06/2010 24/06/2010 "Max. temperature unexpectedly low" "Installed new, straight max/min thermometers. Old 'U' thermometer kept for comparison" "" "" "Lutz 48m" "ETGage" "Installed" "" "" 23/11/2001 23/11/2001 "Install ETGAge at 48m" "" "" "" "Lutz 48m" "Anemometer" "Calibrated" "" "" 24/01/2001 24/01/2001 "Calibrate Anemometer" "<1% difference in speed and direction" "" "" "Lutz 48m" "PAR sensor" "Discontinued" "" "" 24/10/2006 24/10/2006 "Second PAR sensor uninstalled" "This is the sensor that was connected to the LiCor datalogger" "" "" "Lutz 48m" "Thermometer" "Observation" "" "" 24/10/2011 25/10/2011 "Max. temperature unexpectedly low" "Thermometer was broken on Nov 10" "" "" "Lutz 48m" "ETGage" "Modified" "" "" 24/11/2009 24/11/2009 "Replace GorTex covering on ETGage" "Level was 0 when manual measurement was 39mm" "" "" "Lutz 48m" "Battery" "Replaced" "" "" 25/02/2010 25/02/2010 "Replace Battery" "February 25, 2010 - 9:45 am to 10:05 am Replaced the battery by a new one. The old battery was causing the logger to give negative readings for a few of the variables being measured. The battery voltage dopped below 10V on 2010-02-14 23:15:00 and the fi" "rst set of negative readings show up at 04:00:00 that same night. The logger continues to give negative readings for most of the variables collected. The negative readings disappear after the battery was replaced on 2010-02-25. First good line of data a" "fter the battery was replaced:" "Lutz 48m" "Anemometer" "Repaired" "" "" 25/04/2003 25/04/2003 "Repair Anemometer" "" "" "" "Lutz 48m" "Anemometer" "Calibrated" "" "" 25/04/2003 25/04/2003 "Calibrate Anemometer" "Replace the PAR sensors attached to LiCor dataloggers" "" "" "Lutz 48m" "PAR sensor" "Replaced" "" "" 25/04/2003 25/04/2003 "Replace PAR sensors" "" "" "" "Lutz 48m" "Pyranometer" "Discontinued" "" "" 25/04/2003 25/04/2003 "Remove Pyranometer attached to Licor datalogger" "Replace the PAR sensor attached to Campbell datalogger (Lutz1); Started at 8:55hr and finished at 11:20hr" "" "" "Lutz 48m" "PAR sensor" "Replaced" "" "" 25/04/2003 25/04/2003 "Replace PAR sensor" "" "" "" "Lutz 48m" "Pyranometer" "Replaced" "" "" 25/04/2003 25/04/2003 "Replace Pyranometer" "Replace the Pyranometer attached to Campbell datalogger (Lutz1); Started at 8:55hr and finished at 11:20hr" "" "" "Lutz 48m" "T&H sensor" "Replaced" "" "" 25/04/2003 25/04/2003 "Replace Sensor head on Temp/Hum sensor" "Started at 8:55hr and finished at 11:20hr" "" "" "Lutz 48m" "Totalizing Anemometer" "Repaired" "" "" 25/07/2006 26/07/2006 "Repair Totalizing anemometer" "" "" "" "Lutz 48m" "Datalogger" "Battery Replaced" "" "" 25/09/2015 25/09/2015 "Replace Lutz2 datalogger battery" "" "" "" "Lutz 48m" "Thermometer" "Observation" "" "" 26/02/2009 26/02/2009 "Strong winds may have affected max/min temps" "Strong winds caused the tower to strongly sway back and forth. This may have moved the small bar inside the max/min thermometer" "" "" "Lutz 48m" "Enclosure" "Replace shield" "" "" 26/02/2015 23/04/2015 "Changed enclosure" "Feb. 26, 2015 Removed power from logger at 11:45 am -Installed new enclosure -Sensors, logger and programmed remained the same Logger power-up at 14:25" "" "" "Lutz 48m" "Enclosure" "Replace shield" "" "" 26/02/2015 26/02/2015 "Change enclosure" "Feb. 26, 2015 Removed power from logger at 11:45 am -Installed new enclosure -Sensors, logger and programmed remained the same Logger power-up at 14:25" "" "" "Lutz 48m" "Pyranometer" "Replaced" "79566" "73921" 26/05/2014 26/05/2014 "Replace Pyranometer west" "May 26, 2014 Logger shutdwon at 9:50am -Removed LI200s - PY73921 W -Installed LI200s - PY79566 W Logger powerup at 10:33am" "" "" "Lutz 48m" "Pyranometer" "Replaced" "79565" "73920" 26/05/2014 26/05/2014 "Replace Pyranometer east" "May 26, 2014 Logger shutdwon at 9:50am -Removed LI200s - PY73920 E -Installed LI200s - PY79565 E Logger powerup at 10:33am" "" "" "Lutz 48m" "Thermometer" "Observation" "" "" 27/09/2011 27/09/2011 "Max. temperature unexpectedly low" "" "" "" "Lutz 48m" "Anemometer" "Repaired" "" "" 27/11/2007 28/11/2007 "Repair Anemometer" "" "" "" "Lutz 48m" "Thermometer" "Observation" "" "" 28/04/2010 28/04/2010 "Max. temperature unexpectedly low" "" "" "" "Lutz 48m" "ETGage" "Observation" "" "" 28/07/2006 28/07/2006 "Bad data" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz 48m" "Datalogger" "Replaced" "" "" 30/06/2008 30/06/2008 "Replace Lutz2 datalogger" "" "" "" "Lutz 48m" "Thermometer" "Observation" "" "" 30/08/2010 01/12/2010 "Max. temperature unexpectedly low" "" "" "" "Lutz Tower" "Datalogger" "Reprogrammed" "" "" 01/04/1999 01/04/1999 "Modify program to remove unused sensor outputs" "" "" "" "Lutz Tower" "Datalogger" "Reprogrammed" "" "" 03/03/2000 03/03/2000 "Change reporting interval to every 15 minutes" "Campbell PAR sensor too high by 2.3%, LiCor PAR too low by 3.3%. Datalogger programs adjusted to take these differences into account" "" "" "Lutz Tower" "Datalogger" "Reprogrammed" "" "" 05/05/1997 05/05/1997 "Modify program to accept tipping bucket data" "Installed an aluminum bar on the top of the weir to make sure that the top of the weir is really level" "" "" "Lutz Tower" "Infrastructure" "Observation" "" "" 06/06/2014 23/06/2014 "Cut trees around the Lutz tower" "" "" "" "Lutz Tower" "Infrastructure" "Modified" "" "" 06/10/2001 08/10/2001 "Increase height of tower to 48m" "Two sections were added to the tower. New maximum height is 48m" "" "" "Lutz Tower" "Infrastructure" "Observation" "" "" 08/08/2001 10/08/2001 "Trees trimmed around tower" "Trees trimmed to the north and west of the tower in the understory. A few branches on the east side were also cut. The area around the tower at ~30m and 1m seem more open" "" "" "Lutz Tower" "Datalogger" "Replaced" "" "" 09/11/1999 09/11/1999 "Replace Datalogger" "" "" "" "Lutz Tower" "Infrastructure" "Modified" "" "" 13/10/2001 15/10/2001 "Final adjustments to tower" "Totalizing anemometer and ETGage taken down on Oct 13 and replaced on Oct 15" "" "" "Lutz Tower" "Infrastructure" "Observation" "" "" 15/07/2014 15/07/2014 "Lutz tower PVC replacement" "July 15th, 2014 Datalogger shutdown at 10:45am -Disconnected sensors at 10m and 20m -Sensor cables placed inside new pvc tube Datalogger powerup at 13:30" "" "" "Lutz Tower" "Datalogger" "Replaced" "" "" 21/01/2000 21/01/2000 "Replace Datalogger" "" "" "" "Lutz Tower" "Datalogger" "Observation" "" "" 21/06/1999 26/06/1999 "Datalogger damaged in storm" "" "" "" "Lutz Tower" "Infrastructure" "Observation" "" "" 23/02/2011 23/02/2011 "Trees cut down around tower" "" "" "" "Lutz Tower" "Datalogger" "Replaced" "" "" 25/03/1997 25/03/1997 "Replace datalogger" "No good anemometer data between Jan and this date" "" "" "Lutz Tower" "Datalogger" "Replaced" "" "" 25/03/1997 25/03/1997 "Replace datalogger" "" "" "" "Lutz Tower" "Datalogger" "Replaced" "" "" 25/03/1997 25/03/1997 "Replace datalogger" "" "" "" "Lutz Tower" "Datalogger" "Replaced" "" "" 25/03/1997 25/03/1997 "Replace datalogger" "" "" "" "Lutz Tower" "Datalogger" "Replaced" "" "" 25/03/1997 25/03/1997 "Replace datalogger" "" "" "" "Lutz Tower" "Datalogger" "Replaced" "" "" 25/03/1997 25/03/1997 "Replace datalogger" "" "" "" "Lutz Tower" "Enclosure" "Replaced" "" "" 25/03/1997 25/03/1997 "Replace datalogger shelter" "" "" "" "Lutz Tower" "Datalogger" "Replaced" "" "" 26/06/1999 26/06/1999 "Replace Datalogger" "" "" "" "Lutz weir" "ISCO" "Repaired" "" "" 01/01/1990 01/01/1990 "Repair problem with electricity in Lutz" "Stilling pond was over filled following cleaning. Stablized at correct value ~15:00hr" "" "" "Lutz weir" "Radar" "Cleaned" "" "" 01/09/2015 01/09/2015 "Removed frog egg from radar; may have affected measurements" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 02/02/2015 02/02/2015 "Chart recorder stopped" "Water level momentarily too high on 30th while stilling pond was refilled after cleaning" "" "" "Lutz weir" "Infrastructure" "Observation" "" "" 02/03/2015 18/03/2015 "Weir hit by tree" "March 2nd, 2015-Radar arm hit by a tree at on 2015/03/02 @ 16:25 -Radar arm needs to be replaced" "" "" "Lutz weir" "ISCO" "Observation" "" "" 02/04/2001 02/04/2001 "ISCO recording 20mm too high compared to manual" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 02/05/2001 11/05/2001 "ISCO recording ~14mm too high comparted to manual" "ISCO recording 20mm when manual reading is 6mm" "" "" "Lutz weir" "Chart Recorder" "Chip Replaced" "" "" 02/10/1985 02/10/1985 "Replace chip and battery in recorder datapod" "" "" "" "Lutz weir" "Chart Recorder" "Battery Replaced" "" "" 02/11/1985 02/11/1985 "Replace battery in recorder datapod" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 02/11/1988 03/11/1988 "Chart recorder stopped" "" "" "" "Lutz weir" "Radar" "Reprogrammed" "" "" 03/08/2015 03/08/2015 "Load new program w/adjusted FP as IEEEA" "Agust 3, 2015 -Loaded new datalogger code with measure point (measure_point) and water distance (Wdistancemm_Avg) adjusted to record vales as four byte floating point variables. -New datalogger code bci_lutzweir_20150803kk_mm.CR8 was loaded on 2015-08-" "03 @ 13:14" "" "Lutz weir" "Chart Recorder" "Installed" "" "" 03/09/2015 03/09/2015 "Deploy new Stevens typeF chart recorder" "September 3rd, 2015 @ 7:25 am -Deployment of Stevens type with chart and digital encoder water level sensor. -The gear ratio on the initial deployment is 1:2. This is innadequate to record the rapid rising of the Lutz stream during heavy torrential rain" "s. -Uploaded the CR800 logger program bci_lutz_weir_20150825kk_mm.CR8" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 04/01/1988 05/01/1988 "Annual cleaning of weir stilling pond" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 04/04/2001 04/04/2001 "Time synchronized with computer" "ISCO recording -3mm when manual reading is 12mm" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 04/11/1998 04/11/1998 "Paper runs faster as it gets closer to the end" "Cal-1.prn -> PAR data from Campbell loggerCal-2.prn -> PAR data from sensors #13588 & #10456" "" "" "Lutz weir" "Radar" "Cleaned" "" "" 04/11/2015 04/11/2015 "Removed frog egg from radar; may have affected measurements" "" "" "" "Lutz weir" "Chart Recorder" "Calibrated" "" "" 04/12/2007 04/12/2007 "Adjust position of pen" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 05/04/2005 07/04/2005 "Annual cleaning of weir stilling pond" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 05/04/2014 05/04/2014 "Annual cleaning of stilling pond" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 06/01/1997 06/01/1997 "ISCO reading much lowerr than it should be" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 06/01/1997 06/01/1997 "ISCO continues to give problems" "ISCO continues to give problems possibly because of the sediments" "" "" "Lutz weir" "Tipping Bucket" "Calibrated" "" "" 06/03/2014 06/03/2014 "Adjust level of chart recorder +6mm" "" "" "" "Lutz weir" "Stilling Pond" "Observation" "" "" 06/09/1988 22/09/1988 "Build up of sediment in stilling pond" "Build up of sediment. Data between Sept 6 and 22 doubtful" "" "" "Lutz weir" "Stilling Pond" "Observation" "" "" 06/11/1990 06/11/1990 "Accumulated sediment keeping water level too high" "" "" "" "Lutz weir" "Radar" "Installed" "1209391" "" 06/12/2013 12/12/2013 "Install Radar water level system" "Dec. 12, 2013 Deployment of radar water level sensor -Sutron radar RLR-0003-1 REVF SN:1209391 -CR850 datalogger SN:25071 -Zero reference level (zero_ref) set to 2.978m -Logger program: bci_lutz_weir_20131206kk.CR8 Logger power-up at 2:35 pm Outstanding" "items: -Needs new power cable to run between the Lutz tower and the weir hut -Pad lock for instrument box" "" "Lutz weir" "ISCO" "Discontinued" "" "" 06/12/2013 06/12/2013 "Replace ISCO with new Radar system" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 07/01/1987 08/01/1987 "Annual cleaning of weir stilling pond" "" "" "" "Lutz weir" "ISCO" "Reprogrammed" "" "" 07/05/1999 07/05/1999 "Reprogram ISCO to adjust level" "For unknown reasons, Beginning on April 30 @ ~16:00hr the level recorded by the ISCO was 45mm too low. This was corrected on May 3 @ ~10:40hr" "" "" "Lutz weir" "ISCO" "Reprogrammed" "" "" 07/05/1999 07/05/1999 "Reprogram ISCO to adjust level" "For unknown reasons, Beginning on April 30 @ ~16:00hr the level recorded by the ISCO was 45mm too low. This was corrected on May 3 @ ~10:40hr" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 07/06/1988 07/06/1988 "Chart recorder stopped" "" "" "" "Lutz weir" "ISCO" "Repaired" "" "" 07/10/2009 07/10/2009 "Change Voltage Regulator" "The battery of the ISCO at Lutz was discharging during the night.The regulator was changed - problem fixed. Regulator taken out, SN: 1831" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 07/11/2005 07/11/2005 "Clock on chart recorder broken" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 07/11/2006 07/11/2006 "Clock of recorder is broken" "Exact date unsure. Sometime between May 5th and 9th" "" "" "Lutz weir" "ISCO" "Reprogrammed" "" "" 08/01/2013 08/01/2013 "Reprogram ISCO to produce few bubbles. Working better now" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 08/03/1993 11/03/1993 "Annual cleaning of weir stilling pond" "The chart recorder potentiometer (A/D converter) lost its calibration during the sediment cleaning and as a result data were lost until the 15th at 11:40hr. There was rain over the weekend of the 13-14th so the runoff will have to be estimatedfrom the ch" "art." "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 08/04/1996 10/04/1996 "Annual cleaning of weir stilling pond" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz weir" "Enclosure" "Replaced" "" "" 08/10/2014 08/10/2014 "Change Instrument box" "October 8, 2014 Logger shutwdown at 9:50am -Changed instrument box on Lutz weir Logger power-up at 12:25pm" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 09/02/1999 11/02/1999 "Annual cleaning of weir stilling pond" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 09/03/1989 09/03/1989 "Chart recorder stopped" "Due to fire fighting practice in the Clearing, temperatures in the Clearing may have been affected" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 09/04/1998 09/04/1998 "Recorder stopped" "Recorder stopped at 9:02hr apparently because a pin moved without being detected" "" "" "Lutz weir" "Chart Recorder" "Repaired" "" "" 09/04/1998 09/04/1998 "Repair Chart recorder" "ETGage #1 showing problems" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 09/04/2002 12/04/2002 "Annual cleaning of weir stilling pond" "" "" "" "Lutz weir" "Radar" "Calibrated" "" "" 09/04/2015 09/04/2015 "Calibrate Radar" "ETGage replaced with temporary gauge while it is cleaned" "" "" "Lutz weir" "ISCO" "Observation" "" "" 09/05/2011 09/05/2011 "ISCO not working properly" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 10/05/1988 12/05/1988 "Chart recorder stopped from the 10th to the 12th" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 10/05/1999 10/05/1999 "Level recored by ISCO 40mm too high" "ISCO was reading too high. Seems that the bubbler tube was partially obstructed" "" "" "Lutz weir" "ISCO" "Observation" "" "" 10/09/2002 10/09/2002 "No electricity in Lutz. ISCO not working" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 11/03/1993 15/03/1993 "Data lost" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 11/04/1988 12/04/1988 "Chart recorder reads 8mm even though level is <0mm" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 11/04/2000 12/04/2002 "Annual cleaning of weir stilling pond" "" "" "" "Lutz weir" "ISCO" "Repaired" "" "" 11/05/2001 11/05/2001 "Clean bubbler tube, problem resolved" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz weir" "ISCO" "Observation" "" "" 12/04/2001 12/04/2001 "ISCO recording 15mm too low comparted to manual" "" "" "" "Lutz weir" "Chart Recorder" "Chip Replaced" "" "" 12/12/1985 12/12/1985 "Replace chip and battery in recorder datapod" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 12/12/1988 12/12/1988 "Chart recorder stopped" "" "" "" "Lutz weir" "ISCO" "Repaired" "09223" "" 12/12/2011 12/12/2011 "Replace copper tube" "Dec. 12, 2011 Replaced the copper tube on the Lutz-weir ISCO Between 12:00 noon and 12:30 replaced the copper bubble tube on the ISCO 3220 S/N:09223 After replacing the tube the ISCO was reading the appropriate level: 0.124mm" "" "" "Lutz weir" "ISCO" "Observation" "" "" 13/01/2006 13/01/2006 "ISCO not working properly" "ISCO not working properly for unspecified period" "" "" "Lutz weir" "ISCO" "Repaired" "" "" 13/01/2006 13/01/2006 "Repair ISCO" "ISCO not working properly for unspecified period" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 13/04/2013 14/04/2013 "Annual cleaning of stilling pond" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 13/12/1990 14/12/1990 "Clean weir stilling pond" "" "" "" "Lutz weir" "ISCO" "Calibrated" "" "" 13/12/2011 13/12/2011 "Reset level on ISCO @ ~9:50hr" "" "" "" "Lutz weir" "ISCO" "Battery Replaced" "" "" 13/12/2011 13/12/2011 "Replace ISCO battery" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 14/01/1988 15/01/1988 "Chart recorder stopped after last reading" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 14/03/1990 15/03/1990 "Annual cleaning of weir stilling pond" "Cleaning starts ~ 8:45hr. By Mar. 14 11:15hr the data are once again useable" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 14/04/1998 14/04/1998 "Recorder giving problems. Paper moving slowly" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 14/05/2007 16/05/2007 "ISCO not working properly" "Replaced pump using pump from another ISCO bubbler" "" "" "Lutz weir" "Chart Recorder" "Repaired" "" "" 14/07/1989 14/07/1989 "Replace float cable" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 14/10/1996 14/10/1996 "ISCO reading slightly higher than chart recorder" "ISCO was reading 30mm when it should have been72mm" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 14/10/1999 18/10/1999 "Clean weir stilling pond" "" "" "" "Lutz weir" "Chart Recorder" "Repaired" "" "" 15/01/1991 15/01/1991 "Repair Chart recorder" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 15/01/2010 28/01/2010 "ISCO loses calibration easily" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 15/04/2002 15/04/2002 "First good data after cleaning ~15:00hr" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 15/04/2002 15/04/2002 "No electricity in Lutz. ISCO not working" "" "" "" "Lutz weir" "Chart Recorder" "Repaired" "" "" 16/01/2006 16/01/2006 "Repair Chart Recorder. Replaced clock" "Replaced bearings between 9:40 and 10:15hr" "" "" "Lutz weir" "Chart Recorder" "Repaired" "" "" 16/04/1998 16/04/1998 "Repair Chart recorder" "" "" "" "Lutz weir" "Chart Recorder" "Calibrated" "" "" 16/05/1986 16/05/1986 "Calibrate level of Chart recorder" "" "" "" "Lutz weir" "ISCO" "Repaired" "" "" 16/05/2007 16/05/2007 "Repair ISCO" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 16/07/2010 16/07/2010 "ISCO reading too high" "ISCO reading 180mm when manual measurement says 132mm" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 17/03/1992 19/03/1992 "Annual cleaning of weir stilling pond" "" "" "" "Lutz weir" "Chart Recorder" "Calibrated" "" "" 17/04/1986 17/04/1986 "Calibrate level of Chart recorder" "Sensor had been installed moist" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 17/04/2001 18/04/2001 "Annual cleaning of weir stilling pond" "" "" "" "Lutz weir" "ISCO" "Calibrated" "" "" 17/09/2007 17/09/2007 "Adust water level of ISCO" "For some reason the pen was marking a level of 288mm when the manual reading was only 188mm" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 17/09/2014 17/09/2014 "Chart recorder stopped" "Replaced thermometer in order to repaint scale" "" "" "Lutz weir" "Chart Recorder" "Misc" "NA" "NA" 18/01/2016 19/01/2016 "Replaced the Stevens Type-F gears" "" "" "" "Lutz weir" "Radar" "Observation" "" "" 18/03/2015 03/04/2015 "Replace support arm of Radar" "March 2nd, 2015-Radar arm hit by a tree at on 2015/03/02 @ 16:25 -Radar arm needs to be replaced March 18th, 2015 -Installed new CR850 logger, S/N??? -Re-installed the Sutttron Radar RLR-0003-1 REVF S/N 1209391 -Removed CR850 logger, S/N:25071 -On this" "re-installation the datalogger is not sitting the same distance above the water as before. The measure-point currently set at 2968mm is not valid. The measure_point adjustment will be done by the end of June; as the water level is currently bel ow the V" "-notch. -Data logger start time at 14:15" "Lutz weir" "ISCO" "Reprogrammed" "" "" 18/05/2006 18/05/2006 "Adust clock on ISCO" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 18/10/1985 18/10/1985 "Annual cleaning of weir stilling pond" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 18/12/1996 18/12/1996 "ISCO reading much lowerr than it should be" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 18/12/2001 18/12/2001 "ISCO damaged by lightning" "Repaired anemometer @12:00hr" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 19/03/1998 23/03/1998 "Annual cleaning of weir stilling pond" "" "" "" "Lutz weir" "Chart Recorder" "Calibrated" "" "" 19/07/1989 19/07/1989 "Calibrate logger" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 19/12/1988 19/12/1988 "Chart recorder stopped" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 20/03/1995 22/03/1995 "Annual cleaning of weir stilling pond" "ETGage cleaned and put back around 9:45hr" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 20/10/1988 21/10/1988 "Chart recorder stopped" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 21/04/2008 21/04/2008 "Annual cleaning of stilling pond" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 21/10/2002 21/10/2002 "ISCO giving bad data" "ISCO reading bad. Level stays constant and then suddenly goes up and later drops back down." "" "" "Lutz weir" "Chart Recorder" "Repaired" "" "" 21/10/2015 21/10/2015 "Reset pulley beads on stevens typeF" "October 21, 2015 2015/10/21 @ 9:05 am -The pulley beads were reset to the proper position -The pulley were knocked-off thier proper position by very rapid water level rise on 2015/10/19 @ 18:30. The gear ratio (1:2) of the stevens typeF was not able to" " handle such rapid rise of the weir level. At a later date the gear ratio will be changed t o 1:5." "" "Lutz weir" "Chart Recorder" "Observation" "" "" 21/12/1989 28/12/1989 "Not working" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 22/01/1991 22/01/1991 "Annual cleaning of weir stilling pond" "Tower datalogger would not start. Replaced." "" "" "Lutz weir" "ISCO" "Observation" "" "" 22/03/2010 22/03/2010 "ISCO reading -2mm when manual value is 13mm" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 22/05/1989 22/05/1989 "Chart recorder stopped" "" "" "" "Lutz weir" "Radar" "Reprogrammed" "" "" 22/08/2014 22/08/2014 "Change radar settings" "Document changes on Lutzweir_radar_settings 8/22/2014Started logger at 10:35 am >SETUP Automeasure Interval = 00:00:01 Automeasure Time = 00:00:00 Operating Mode = Normal Avg Time = 5.000" "sec Right Digits = 4 Stage Units = m Measuring Point = 0.00000 m DQAP = Disabled Discharge Enable = Disabled Station Name = LUTZ WEIR WDID" " = 35 Auto Output = Disabled Log Every Subsample = Disabled Log Every Sample = Disabled Log Stage Details = Disabled Log Daily Values = Disabled Sample Form Period" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 22/09/1988 23/09/1988 "Remove sediment from weir stilling pond" "Sunburning UV sensor not working the counter is very fast and the counter on the half hour does not register anything" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 22/09/2003 22/09/2003 "Recorder stops frequently" "" "" "" "Lutz weir" "Chart Recorder" "Repaired" "" "" 22/09/2003 22/09/2003 "Change clock mechanism on recorder" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 22/09/2014 22/09/2014 "Chart recorder stopped" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 23/01/1997 27/01/1997 "Annual cleaning of weir stilling pond" "Occasional bad data due to the intrusion of water into the ETGage due to heavy rain" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 23/04/2012 24/04/2012 "Annual cleaning of stilling pond" "" "" "" "Lutz weir" "Radar" "Reprogrammed" "" "" 23/07/2015 23/07/2015 "Load new program w/adjusted measure_point" "July 23rd, 2015 -Loaded new program bci_lutzweir_20150723kk_mm.CR8 into the Lutz_weir logger @ 12:18 pm -The new program has the proper measure_point, (2904.5 mm) that should have been applied to get level from measure_point - wdistance from 2015/03/18" "@ 14:15 onwards. -Water level values (bci_lutzweir_level) between 2015/03/18 @14:15 and 2015/07/23 @9:45 must be subtracted by 63.5mm in order to obtain the correct water level -Water level will be collected as water distance (bci_lutzweir_wdistmm) in" "mm instead of computed level Used a FP2 value to record water distance and measure point. This format does not have enough significant digits. As such both wdistmm and msrpoint are rounded to the next mm. This got fixed on the next version of the logger" "Lutz weir" "Chart Recorder" "Observation" "" "" 23/09/2013 23/09/2013 "Chart recorder stopped" "" "" "" "Lutz weir" "ISCO" "Calibrated" "" "" 23/11/2010 23/11/2010 "Reset level to match manual value" "Max. temperature unexpectedly low on Jan 3 & Feb 3" "" "" "Lutz weir" "ISCO" "Observation" "" "" 24/02/2010 24/02/2010 "ISCO found shut off" "" "" "" "Lutz weir" "Chart Recorder" "Repaired" "" "" 24/05/1991 24/05/1991 "Replace clock on chart recorder" "Batteries found to be discharged. Replaced at 14:00hr" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 24/09/1986 25/09/1986 "Clean weir stilling pond" "" "" "" "Lutz weir" "Battery" "Replaced" "" "" 25/02/2010 25/02/2010 "Replace battery and power regulator for Lutz1" "" "" "" "Lutz weir" "Chart Recorder" "Repaired" "" "" 25/05/1989 25/05/1989 "Change Chart recorder clock" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 25/12/2012 08/01/2013 "ISCO not working properly" "" "" "" "Lutz weir" "Radar" "Reprogrammed" "" "" 26/01/2015 26/01/2015 "Level converted to mm" "Jan 26, 2015 Uploaded logger program bci_lutz_weir_20150126kk_mm.cr8, level is given in mm. Measuring point redefined in mm" "" "" "Lutz weir" "ISCO" "Observation" "" "" 26/07/2011 26/07/2011 "Weir reading 8mm low" "" "" "" "Lutz weir" "Stilling Pond" "Observation" "" "" 26/10/1992 26/10/1992 "Stilling pond full of sediment" "" "" "" "Lutz weir" "ISCO" "Observation" "" "" 26/11/2009 26/11/2009 "ISCO found disconnected from battery" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 27/03/2010 30/03/2010 "Annual cleaning of weir stilling pond" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 27/03/2015 30/03/2015 "Annual cleaning of stilling pond" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 27/07/2001 27/07/2001 "Recorder stopped. Data not recored" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 27/09/1988 29/09/1988 "Chart recorder stopped" "" "" "" "Lutz weir" "Radar" "Reprogrammed" "" "" 27/11/2014 26/10/2015 "Change the logger program - Adjusted measure_point" "November 27, 2014 New logger program uploaded on 2014/11/27 @ 17:15 New program: bci_lutz_weir_20141127kk.CR8 In this program the measure_point, which is the distance between the radar and the bottom of the weir's V-notch was adjusted down by 10mm. This" " reflects a set measurement comparisons taken over 2.5 months, where the stevens chart recorder, the manual (r uler) and the radar measurements were compared. In the aforementioned program the mesaure-point was set 2.968m. Ins the previous program this" " value had been set to 2.978m." "Lutz weir" "Radar" "Reprogrammed" "" "" 28/01/2015 28/01/2015 "Load logger program" "January 28, 2015 Re-uploaded bci_lutz_weir_20150126kk_mm.cr8 In this program the variable siunits was renamed as radar_siunits. This change has no impact on the data collected it only makes it clear that the radar measures in m and the program coverts l" "evel to mm." "" "Lutz weir" "" "Observation" "" "" 28/01/2015 28/01/2015 "See note" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 28/12/1988 28/12/1988 "Chart recorder stopped" "" "" "" "Lutz weir" "ISCO" "Repaired" "" "" 29/01/2010 29/01/2010 "Clean tube to correct problems with calibration" "tipping bucket observed to be registering false tips when visited on April 23 and May 10" "" "" "Lutz weir" "Datalogger" "Reprogrammed" "NA" "NA" 29/02/2016 29/02/2016 "Loaded new program to adjust the typeFoffset" "" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 29/05/1989 29/05/1989 "Chart recorder stopped" "" "" "" "Lutz weir" "Chart Recorder" "Replaced" "" "" 29/05/1989 29/05/1989 "Replace Flowmeter" "" "" "" "Lutz weir" "Datalogger" "Replaced" "" "" 29/06/1989 29/06/1989 "Replace Chart recorder datalogger" "Replace Vaisala wind direction sensor with Young anemometer" "" "" "Lutz weir" "Stilling Pond" "Observation" "" "" 29/12/1987 29/12/1987 "Build up of sediment in stilling pond" "" "" "" "Lutz weir" "Chart Recorder" "Battery Replaced" "" "" 29/12/1989 29/12/1989 "Replace battery" "Data lost due to technician error. Manual data estimated from tipping bucket data" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 30/03/2009 30/03/2009 "Annual cleaning of stilling pond" "Refilling of the stilling pond resulted in an artificially high reading on April 30" "" "" "Lutz weir" "" "Modified" "" "" 30/03/2010 30/03/2010 "Replace ruler on wall of weir hut" "tipping bucket observed to be registering false tips when visited on April 23 and May 10" "" "" "Lutz weir" "ISCO" "Observation" "" "" 30/04/1999 07/05/1999 "Level recored by ISCO 45mm too low" "For unknown reasons, Beginning on April 30 @ ~16:00hr the level recorded by the ISCO was 45mm too low. This was corrected on May 3 @ ~10:40hr" "" "" "Lutz weir" "Chart Recorder" "Discontinued" "NA" "NA" 30/06/2016 01/07/2016 "Stevens typeF chart recorder re-adjustment after heavy rainfall" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 30/10/1992 04/11/1992 "Partial cleaning of weir stilling pond" "Weir cleaning on Oct 30, Nov 2 & 4 without draining the pond first" "" "" "Lutz weir" "Chart Recorder" "Observation" "" "" 30/12/1988 30/12/1988 "Chart recorder stopped" "" "" "" "Lutz weir" "ISCO" "Calibrated" "" "" 30/12/2009 30/12/2009 "ISCO level reset" "" "" "" "Lutz weir" "Stilling Pond" "Cleaned" "" "" 31/01/1989 01/02/1989 "Annual cleaning of weir stilling pond" "" "" ""